ELG-100U series
April 30, 2022ELG-150U series
April 30, 2022MW Mean Well Meanwell 84-150W Constant Voltage + Constant Current LED Driver ELG-150 series
Features
- Constant Voltage + Constant Current mode output
- Metal housing design with functional Ground
- Built-in active PFC function
- No load / Standby power consumption <0.5W
- IP67 / IP65 rating for indoor or outdoor installations
- Function options: output adjustable via potentiometer;
- 3 in 1 dimming (dim-to-off); Smart timer dimming; DALI; Auxiliary DC output
- Typical lifetime>50000 hours
- 5 years warranty
Mean Well LED Driver ELG-150 Series Data Sheet Download
Description
ELG-150 series is a 150W AC/DC LED driver featuring the dual mode constant voltage and constant current output. ELG-150 operates from 100~305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the high efficiency up to 91%, with the fanless design, the entire series is able to operate for -40℃ ~ +90℃ case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. ELG-150 is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Mean Well LED Driver ELG-150 Series Model Encoding
Type | IP Level | Function | Note |
Blank | IP67 | Io and Vo fixed. | In Stock |
A | IP65 | Io and Vo adjustable through built-in potentiometer. | In Stock |
B | IP67 | 3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance) | In Stock |
AB | IP65 | Io and Vo adjustable through built-in potentiometer &
3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance) |
In Stock |
DA | IP67 | DALI control technology. | In Stock |
Dx | IP67 | Built-in Smart timer dimming function by user request. | By request |
D2 | IP67 | Built-in Smart timer dimming and programmable function. | In Stock |
BE | IP67 | 3 in 1 dimming function and Auxiliary DC output | In Stock |
Specification
MODEL | ELG-150-12 | ELG-150-24 | ELG-150-36 | ELG-150-42 | ELG-150-48 | ELG-150-54 | ||
OUTPUT |
DC VOLTAGE | 12V | 24V | 36V | 42V | 48V | 54V | |
CONSTANT CURRENT REGION Note.2 | 6 ~ 12V | 12 ~ 24V | 18 ~ 36V | 21 ~ 42V | 24 ~ 48V | 27 ~ 54V | ||
RATED CURRENT | 10A | 6.25A | 4.17A | 3.57A | 3.13A | 2.8A | ||
RATED CURRENT(for BE Type only) | 8A | 5.6A | 3.73A | 3.2A | 2.8A | 2.5A | ||
RATED POWER |
100VAC ~ 180VAC | |||||||
(For All the Types) | 84W | 105W | 105W | 105W | 105W | 105W | ||
200VAC ~ 305VAC | ||||||||
(Except for BE Type) | 120W | 150W | 150.1W | 150W | 150.2W | 151.2W | ||
(For BE Type only) | 96W | 134.4W | 134.28W | 134.4W | 134.4W | 135W | ||
RIPPLE & NOISE (max.) Note.3 | 150mVp-p | 200mVp-p | 250mVp-p | 250mVp-p | 250mVp-p | 350mVp-p | ||
VOLTAGE ADJ. RANGE |
Adjustable for A/AB-Type only (via the built-in potentiometer) | |||||||
10.8 ~ 13.2V | 21.6 ~ 26.4V | 32.4 ~ 39.6V | 37.8 ~ 46.2V | 43.2 ~ 52.8V | 49 ~ 58V | |||
CURRENT ADJ. RANGE |
Adjustable for A/AB-Type only (via the built-in potentiometer) | |||||||
5 ~ 10A | 3.2 ~ 6.25A | 2.1 ~ 4.17A | 1.8 ~ 3.57A | 1.56 ~ 3.13A | 1.4 ~ 2.8A | |||
VOLTAGE TOLERANCE Note.4 | ±3.0% | ±3.0% | ±2.5% | ±2.5% | ±2.0% | ±2.0% | ||
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||
LOAD REGULATION | ±2.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ||
AUXILIARY DC OUTPUT | Nominal 15V(deviation 11.5~15.5V)@0.3A for BE-Type only | |||||||
SETUP, RISE TIME Note.6 | 1600ms, 80ms/115VAC 500ms, 100ms/230VAC | |||||||
HOLD UP TIME (Typ.) | 10ms/115VAC, 230VAC | |||||||
INPUT |
VOLTAGE RANGE Note.5 |
100 ~ 305VAC 142 ~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” section) |
||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
POWER FACTOR | PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section) |
|||||||
TOTAL HARMONIC DISTORTION |
THD< 20%(@load≧50%/115VC; @load≧60%/230VAC; @load≧75%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section) | |||||||
EFFICIENCY (Typ.) | 88.5% | 89% | 90% | 90% | 90% | 91% | ||
EFFICIENCY (Typ.)(for BE Type only) | 86% | 89% | 89% | 89% | 89% | 89% | ||
AC CURRENT | 1.7A / 115VAC 0.9A / 230VAC 0.7A/277VAC | |||||||
INRUSH CURRENT(Typ.) | COLD START 65A(twidth=550μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | |||||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | |||||||
LEAKAGE CURRENT | <0.75mA / 277VAC | |||||||
NO LOAD / STANDBY POWER CONSUMPTION | No load power consumption <0.5W for Blank / A / Dx / D2-Type Standby power consumption <0.5W for B / AB / DA-Type | |||||||
PROTECTION |
OVER CURRENT |
95 ~ 108% | ||||||
Constant current limiting, recovers automatically after fault condition is removed | ||||||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE |
14 ~ 18V | 28 ~ 34V | 41 ~ 48V | 47 ~ 54V | 54 ~ 62V | 59 ~ 68V | ||
Shut down output voltage, re-power on to recover | ||||||||
OVER TEMPERATURE | Shut down output voltage, re-power on to recover | |||||||
ENVIRONMENT |
WORKING TEMP. | Tcase=-40 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section) | ||||||
MAX. CASE TEMP. | Tcase=+90℃ | |||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | |||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 60℃) | |||||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||
SAFETY & EMC |
SAFETY STANDARDS |
UL8750(type”HL”)(except for BE-type), CSA C22.2 No. 250.13-12;IEC/BS EN/EN/AS/NZS 61347-1,IEC/BS EN/EN/AS/NZS 61347-2-13
independent,BS EN/EN62384,BIS IS15885(for 12/12A/12B/12DA/24/24A/24B/24DA/36A/36B/42/42A/42B/48A/48B/54/54A/54B only), EAC TP TC 004,GB19510.1,GB19510.14; IP65 or IP67; KC61347-1,KC61347-2-13 approved |
||||||
DALI STANDARDS | Compliance to IEC62386-101,102,(207 by request) for DA Type only | |||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||
EMC EMISSION | Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C (@load≧60%) ; BS EN/EN61000-3-3; Gb17743,GB17625.1, EAC TP TC 020; KC KN15,KN61547 | |||||||
EMC IMMUNITY |
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV),EAC TP TC 020; KC KN15,KN61547 | |||||||
OTHERS |
MTBF | 899.8K hrs min. Telcordia SR-332 (Bellcore) 313.66Khrs min. MIL-HDBK-217F (25℃) | ||||||
DIMENSION | 219*63*35.5mm (L*W*H) | |||||||
PACKING | 0.95Kg ; 16pcs/16.0kg/0.77CUFT |
Application
- LED street lighting
- LED architectural lighting
- LED bay lighting
- LED floodlighting
- Type “HL” for use in Class I, Division 2 hazardous (Classified)