Features
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
350% peak power capability
Built-in constant current limiting circuit
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in cooling fan ON-OFF control
Built-in DC OK signal
Built-in remote sense function
Withstand 5G vibration
Oprating altitude up to 5000 meters
Output votage adjustable ±15%(Avg.)
1U low profile 41mm
5 years warranty
Description
MEAN WELL HRP-300N3 series is a 300W single output AC/DC ultra-high peak power supply. This series operates at 85~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan ON-OFF control, working for the temperature up to 70℃.Moreover, MW HRP-300N3 can provide 350% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.
Mean Well Ultra-high Peak Power Supply HRP-300N3 Series Data Sheet Download
Mean Well Ultra-high Peak Power Supply HRP-300N3 Series Model Encoding
Specification
MODEL | HRP-300N3-12 | HRP-300N3-24 | HRP-300N3-36 | HRP-300N3-48 | |||
OUTPUT |
DC VOLTAGE | 12V | 24V | 36V | 48V | ||
RATED CURRENT | 27A | 14A | 9A | 7A | |||
CURRENT RANGE | 0 ~ 27A | 0 ~ 14A | 0 ~ 9A | 0 ~ 7A | |||
RATED POWER | 324W | 336W | 324W | 336W | |||
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | 150mVp-p | 250mVp-p | 250mVp-p | |||
VOLTAGE ADJ. RANGE | 10.2 ~ 13.8V | 21.6 ~ 28.8V | 28.8 ~ 39.6V | 40.8 ~ 55.2V | |||
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
LINE REGULATION | ±0.3% | ±0.2% | ±0.2% | ±0.2% | |||
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
SETUP, RISE TIME | 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load | ||||||
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC at full load | ||||||
INPUT |
VOLTAGE RANGE Note.4 | 85 ~ 264VAC 120 ~ 370VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
POWER FACTOR (Typ.) | PF>0.95/230VAC PF>0.99/115VAC at full load | ||||||
EFFICIENCY (Typ.) | 88% | 87% | 88% | 89% | |||
AC CURRENT (Typ.) | 3.5A/115VAC 1.8A/230VAC | ||||||
INRUSH CURRENT (Typ.) | 35A/115VAC 75A/230VAC | ||||||
LEAKAGE CURRENT | <2mA / 240VAC | ||||||
PROTECTION |
OVERLOAD |
Output power >105% rated for more than 5 seconds then shut down o/p voltage, re-power on to recover | |||||
Constant current limiting for output power >380%(1140W) rated for more than 5 seconds and then shut down o/p voltage, re-power on to recover | |||||||
OVER VOLTAGE | 14.4 ~ 16.8V | 30 ~ 34.8V | 41.4 ~ 48.6V | 57.6 ~ 67.2V | |||
Protection type: Shut down o/p voltage, re-power on to recover | |||||||
OVER TEMPERATURE | TSW1: Shut down o/p voltage, recovers automatically after temperature goes down RTH3: Shut down o/p voltage, re-power on to recover | ||||||
FUNCTION | DC OK SIGNAL | PSU turns on: 3.3 ~ 5.6V; PSU turns off : 0 ~ 1V | |||||
FAN CONTROL (Typ.) | Load 35±15% or RTH2≧50℃ Fan on | ||||||
ENVIRONMENT |
WORKING TEMP. | -40 ~ +70℃ (Refer to “Derating Curve”) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||||
TEMP. COEFFICIENT | ±0.03%/ ℃ (0 ~ 50℃) | ||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
OPERATING ALTITUDE Note.5 | 5000 meters | ||||||
SAFETY & EMC (Note 6) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, AS/NZS 62368.1 approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION |
Parameter | Standard | Test Level / Note | ||||
Conducted | BS EN/EN55032 | Class B | |||||
Radiated | BS EN/EN55032 | Class B | |||||
Harmonic current | BS EN/EN61000-3-2 | Class A | |||||
Voltage Flicker | BS EN/EN61000-3-3 | —– | |||||
EMC IMMUNITY |
BS EN/EN55035, BS EN/EN61000-6-2(BS EN/EN50082-2) | ||||||
Parameter | Standard | Test Level / Note | |||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air; Level 2, 4KV contact | |||||
RF field | BS EN/EN61000-4-3 | Level 3, 10V/m | |||||
EFT/ Burst | BS EN/EN61000-4-4 | Level 3, 2KV | |||||
Surge | BS EN/EN61000-4-5 | Level 4, 4KV/Line-FG; 2KV/Line-Line | |||||
Conducted | BS EN/EN61000-4-6 | Level 3, 10V | |||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4, 30A/m | |||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | 95% dip 0.5 periods, 30% dip 25 periods,
95% interruptions 250 periods |
|||||
OTHERS |
MTBF | 1524.0K hrs min. Telcordia TR/SR-332 (Bellcore); 187.7K hrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 199*105*41mm (L*W*H) | ||||||
PACKING | 0.9Kg; 15pcs/14.5Kg/0.84CUFT |
Application
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Diagnostic or biological facilities
- Test or measurement systems