RSP-750 series
June 30, 2023RSP-1500 series
June 30, 2023MW Mean Well Meanwell 1000W Single Output with PFC Fucntion Switching Power Supply RSP-1000 series
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 90%
- Forced air cooling by built-in DC fan
- Output voltage programmable
- Active current sharing up to 4000W
- Built-in remote ON-OFF control / remote sense / auxiliary power / DC OK signal
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Optional conformal coating
- 5 years warranty
Mean Well Enclosed Switching Power Supply RSP-1000 Series Data Sheet Download
Description
Mean Well RSP-1000 is a 1KW single output enclosed type AC/DC power supply with 1U low profile and PFC function. This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan speed control, working for the temperature up to 60℃. Moreover, RSP-1000 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.
Mean Well Enclosed Switching Power Supply RSP-1000 Series Model Encoding
Specification
MODEL | RSP-1000-12 | RSP-1000-15 | RSP-1000-24 | RSP-1000-27 | RSP-1000-48 | |||
OUTPUT |
DC VOLTAGE | 12V | 15V | 24V | 27V | 48V | ||
RATED CURRENT | 60A | 50A | 40A | 37A | 21A | |||
CURRENT RANGE | 0 ~ 60A | 0 ~ 50A | 0 ~ 40A | 0 ~ 37A | 0 ~ 21A | |||
RATED POWER | 720W | 750W | 960W | 999W | 1008W | |||
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |||
VOLTAGE ADJ. RANGE | 10 ~ 13.5V | 13.5 ~ 16.5V | 20 ~ 26.4V | 24 ~ 30V | 43 ~ 55V | |||
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
SETUP, RISE TIME | 300ms, 50ms at full load | |||||||
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC at full load | |||||||
INPUT |
VOLTAGE RANGE Note.4 | 90 ~ 264VAC 127 ~ 370VDC | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
POWER FACTOR (Typ.) | 0.95/230VAC 0.98/115VAC at full load | |||||||
EFFICIENCY (Typ.) | 83% | 85% | 88% | 88% | 90% | |||
AC CURRENT (Typ.) | 12A/115VAC 6A/230VAC | |||||||
INRUSH CURRENT (Typ.) | 25A/115VAC 40A/230VAC | |||||||
LEAKAGE CURRENT | <2.0mA / 240VAC | |||||||
PROTECTION |
OVERLOAD | 105 ~ 125% rated output power | ||||||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE | 13.8 ~ 16.8V | 17 ~ 20.5V | 27.6 ~ 32.4V | 31 ~ 36.5V | 56.6 ~ 66.2V | |||
Protection type: Shut down o/p voltage, re-power on to recover | ||||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |||||||
FUNCTION |
OUTPUT VOLTAGE PROGRAMMABLE(PV) | Adjustment of output voltage is allowable to 40 ~ 110% of nominal output voltage. Please refer to the Function Manual. | ||||||
CURRENT SHARING | Up to 4000W or (3+1) units. Please refer to the Function Manual. | |||||||
AUXILIARY POWER | 5V @ 0.5A (+5%, -8%) | |||||||
REMOTE ON-OFF CONTROL | Power ON: short Power OFF: open. Please refer to the Function Manual. | |||||||
REMOTE SENSE | Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual. | |||||||
DC OK SIGNAL | The TTL signal out, PSU turn on = 0 ~ 1V; PSU turn off = 3.3 ~ 5.6V. Please refer to the Function Manual. | |||||||
ENVIRONMENT |
WORKING TEMP. | -20 ~ +60℃ (Refer to “Derating Curve”) | ||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFICIENT | ±0.02%/℃ (0 ~ 50℃) | |||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||
SAFETY & EMC (Note 5) |
SAFETY STANDARDS | UL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, CCC GB4943.1, BSMI CNS14336-1, AS/NZS62368.1, IS13252(Part1)/IEC60950-1, EAC TP TC 004 approved | ||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||
EMC EMISSION |
Parameter | Standard | Test Level / Note | |||||
Conducted | BS EN/EN55032 (CISPR32) | Class B | ||||||
Radiated | BS EN/EN55032 (CISPR32) | Class A | ||||||
Harmonic Current | BS EN/EN61000-3-2 | —– | ||||||
Voltage Flicker | BS EN/EN61000-3-3 | —– | ||||||
EMC IMMUNITY |
BS EN/EN55035, BS EN/EN61000-6-2, CCC GB17625.1, GB/T9254, BSMI CNS13438 | |||||||
Parameter | Standard | Test Level / Note | ||||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | ||||||
Radiated | BS EN/EN61000-4-3 | Level 3 | ||||||
EFT / Burst | BS EN/EN61000-4-4 | Level 3 | ||||||
Surge | BS EN/EN61000-4-5 | Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line | ||||||
Conducted | BS EN/EN61000-4-6 | Level 3 | ||||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | ||||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 peniods,
>95% interruptions 250 periods |
||||||
OTHERS |
MTBF | 939.4K hrs min. Telcordia SR-332 (Bellcore); 116.5K hrs min. MIL-HDBK-217F (25℃) | ||||||
DIMENSION | 295*127*41mm (L*W*H) | |||||||
PACKING | 1.95Kg; 6pcs/12.7Kg/1.15CUFT |
Application
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Burn-in facility
- RF application