RSP-1500 series
June 30, 2023RSP-2000 series
June 30, 2023MW Mean Well Meanwell 1600W Single Output with PFC Fucntion Switching Power Supply RSP-1600 series
Features
- Universal AC input / Full range (Withstand 300VAC surge input for 5 seconds)
- Built-in active PFC function
- High efficiency up to 93%
- Forced air cooling by built-in DC fan
- Output voltage and constant current level programmable
- Active current sharing up to 9600W
- Built-in remote ON-OFF control / remote sense / auxiliary power / DC OK signal
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Optional PMBus or CANBus protocol
- 5 years warranty
Mean Well Enclosed Switching Power Supply RSP-1600 Series Data Sheet Download
Description
Mean Well RSP-1600 is a 1.6KW single output enclosed type AC/DC power supply with a 1U low profile and a high power density up to 25W/inch3. This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the thermostatically controlled fan. Moreover, RSP-1600 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.
Mean Well Enclosed Switching Power Supply RSP-1600 Series Model Encoding
Type | Communication Protocol | Note |
Blank | None | In Stock |
PM | PMBus protocol | By request |
CAN | CANBus protocol | By request |
Specification
MODEL | RSP-1600-12 | RSP-1600-24 | RSP-1600-27 | RSP-1600-36 | RSP-1600-48 | |||
OUTPUT |
DC VOLTAGE | 12V | 24V | 27V | 36V | 48V | ||
RATED CURRENT | 125A | 67A | 59A | 44.5A | 33.5A | |||
CURRENT RANGE | 0 ~ 125A | 0 ~ 67A | 0 ~ 59A | 0 ~ 44.5A | 0 ~ 33.5A | |||
RATED POWER | 1500W | 1608W | 1593W | 1602W | 1608W | |||
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 200mVp-p | 200mVp-p | 250mVp-p | 300mVp-p | |||
VOLTAGE ADJ. RANGE | 11.5 ~ 15V | 23.5 ~ 30V | 26.5 ~ 33.5V | 35.5 ~ 45V | 47.5 ~ 58.8V | |||
VOLTAGE TOLERANCE Note.4 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
SETUP, RISE TIME | 1500ms, 60ms/230VAC at full load | |||||||
HOLD UP TIME (Typ.) | 16ms / 230VAC at 75% load 10ms / 230VAC at full load | |||||||
INPUT |
VOLTAGE RANGE Note.5 | 90 ~ 264VAC 250 ~ 370VDC | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
POWER FACTOR (Typ.) | 0.97/230VAC at full load | |||||||
EFFICIENCY (Typ.) | 89% | 91.5% | 92% | 92% | 93% | |||
AC CURRENT (Typ.) Note.5 | 14A/115VAC 8A/230VAC | 15A/115VAC 8.5A/230VAC | ||||||
INRUSH CURRENT (Typ.) | COLD START 35A/230VAC | |||||||
LEAKAGE CURRENT | <2mA / 230VAC | |||||||
PROTECTION |
OVERLOAD |
105 ~ 115% rated current | ||||||
Protection type: Constant current limiting, shut down O/P voltage after 5 sec. After O/P voltage falls, re-power on to recover | ||||||||
OVER VOLTAGE |
15.75 ~ 18.75V | 31.5 ~ 37.5V | 35.2 ~ 41.9V | 47.2 ~ 56.3V | 63 ~ 75V | |||
Protection type: Shut down o/p voltage, re-power on to recover | ||||||||
OVER TEMPERATURE | Protection type: Shut down o/p voltage, recovers automatically after temperature goes down | |||||||
FUNCTION |
OUTPUT VOLTAGE PROGRAMMABLE(PV) Note 6 | Adjustment of output voltage is allowable to 40 ~ 125% of nominal output voltage (60 ~ 125% for 12V). Please refer to the Function Manual. | ||||||
OUTPUT CURRENT PROGRAMMABLE(PC) Note 6 | Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual. | |||||||
AUXILIARY POWER | 5V @ 0.3A, 12V @ 0.8A | |||||||
REMOTE ON-OFF CONTROL | By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual | |||||||
REMOTE SENSE | Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual | |||||||
ALARM SIGNAL | Isolated signal output for T-alarm and DC OK | |||||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | ||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||
SAFETY & EMC (Note 8) |
SAFETY STANDARDS | UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS14336-1, AS/NZS62368.1, EAC TP TC 004 approved | ||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||
EMC EMISSION |
Parameter | Standard | Test Level / Note | |||||
Conducted | BS EN/EN55032 (CISPR32) | Class B | ||||||
Radiated | BS EN/EN55032 (CISPR32) | Class A | ||||||
Harmonic Current | BS EN/EN61000-3-2 | Class A | ||||||
Voltage Flicker | BS EN/EN61000-3-3 | —– | ||||||
EMC IMMUNITY |
BS EN/EN55035, BS EN/EN61000-6-2, BSMI CNS13438 | |||||||
Parameter | Standard | Test Level / Note | ||||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | ||||||
Radiated | BS EN/EN61000-4-3 | Level 3 | ||||||
EFT / Burst | BS EN/EN61000-4-4 | Level 3 | ||||||
Surge | BS EN/EN61000-4-5 | Level 4, 2KV/Line-Line 4KV/Line-Earth | ||||||
Conducted | BS EN/EN61000-4-6 | Level 3 | ||||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | ||||||
Voltage Dips and Interruptions |
BS EN/EN61000-4-11 |
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
||||||
OTHERS |
MTBF | 478.8K hrs min. Telcordia SR-332 (Bellcore); 42.1K hrs min. MIL-HDBK-217F (25℃) | ||||||
DIMENSION | 300*85*41mm (L*W*H) | |||||||
PACKING | 2.1Kg; 6pcs/13.6Kg/1.25CUFT |
Application
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Aging facility
- Digital broadcasting
- Constant current source
- Redundant system