RSP-2000 series
June 30, 2023RSP-3000 series
June 30, 2023MW Mean Well Meanwell 2400W Single Output with PFC Fucntion Switching Power Supply RSP-2400 series
Features
- AC input 180~264VAC
- Built-in active PFC function
- High efficiency up to 91.5%
- Forced air cooling by built-in DC fan
- Output voltage programmable
- Active current sharing up to 7200W
- Built-in remote ON-OFF control / remote sense / auxiliary power / DC OK signal
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Optional conformal coating
- 5 years warranty
Mean Well Enclosed Switching Power Supply RSP-2400 Series Data Sheet Download
Description
Mean Well RSP-2400 is a 2.4KW single output enclosed type AC/DC power supply with PFC function. This series operates for 180~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan speed control, working for the temperature up to 70℃. Moreover, RSP-2400 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.
Mean Well Enclosed Switching Power Supply RSP-2400 Series Model Encoding
Specification
MODEL | RSP-2400-12 | RSP-2400-24 | RSP-2400-48 | |
OUTPUT |
DC VOLTAGE | 12V | 24V | 48V |
RATED CURRENT | 166.7A | 100A | 50A | |
CURRENT RANGE | 0 ~ 166.7A | 0 ~ 100A | 0 ~ 50A | |
RATED POWER | 2000.4W | 2400W | 2400W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 10.8 ~ 13.2V | 22 ~ 28V | 43 ~ 56V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1000ms, 80ms at full load | |||
HOLD UP TIME (Typ.) | 12ms at full load | |||
INPUT |
VOLTAGE RANGE | 180 ~ 264VAC 254 ~ 370VDC | ||
FREQUENCY RANGE | 47 ~ 63Hz | |||
POWER FACTOR (Typ.) | 0.95/230VAC at full load | |||
EFFICIENCY (Typ.) | 88% | 90.5% | 91.5% | |
AC CURRENT (Typ.) | 15.5A/180VAC 12A/230VAC | |||
INRUSH CURRENT (Typ.) | 60A/230VAC | |||
LEAKAGE CURRENT | <2.0mA / 240VAC | |||
PROTECTION |
OVERLOAD (OLP) |
100 ~ 112% rated output power | ||
User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover | ||||
OVER VOLTAGE |
13.8 ~ 16.8V | 28.8 ~ 33.6V | 57.6 ~ 67.2V | |
Protection type: Shut down o/p voltage, re-power on to recover | ||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |||
FUNCTION |
OUTPUT VOLTAGE PROGRAMMABLE(PV) | 2.4 ~ 13.2V | 4.8 ~ 28V | 9.6 ~ 56V |
Please refer to the Function Manual. | ||||
CURRENT SHARING | Up to 7200W or (2+1) units. Please refer to the Function Manual. | |||
AUXILIARY POWER | [email protected] (Only for Remote ON-OFF control) | |||
REMOTE ON-OFF CONTROL | Please refer to the Function Manual | |||
REMOTE SENSE | Compensate voltage drop on the load wiring up to 0.25V. Please refer to the Function Manual. | |||
ALARM SIGNAL OUTPUT | Power OK signal. Please refer to the Function Manual | |||
ENVIRONMENT |
WORKING TEMP. | -20 ~ +70℃ (Refer to “Derating Curve”) | ||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | |||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS | UL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS14336-1, AS/NZS62368.1,IS13252(Part1)/IEC60950-1,
EAC TP TC 004 approved |
||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||
EMC EMISSION |
Parameter | Standard | Test Level / Note | |
Conducted | BS EN/EN55032 (CISPR32) | Class B | ||
Radiated | BS EN/EN55032 (CISPR32) | Class A | ||
Harmonic Current | BS EN/EN61000-3-2 | —– | ||
Voltage Flicker | BS EN/EN61000-3-3 | —– | ||
EMC IMMUNITY |
BS EN/EN55035, BS EN/EN61000-6-2, BSMI CNS13438 | |||
Parameter | Standard | Test Level / Note | ||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | ||
Radiated | BS EN/EN61000-4-3 | Level 3 | ||
EFT / Burst | BS EN/EN61000-4-4 | Level 3 | ||
Surge | BS EN/EN61000-4-5 | Level 3, 2KV/Line-Earth ; Level 2, 1KV/Line-Line | ||
Conducted | BS EN/EN61000-4-6 | Level 3 | ||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | ||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
||
OTHERS |
MTBF | 692.3K hrs min. Telcordia SR-332 (Bellcore); 83.9K hrs min. MIL-HDBK-217F (25℃) | ||
DIMENSION | 278*177.8*63.5mm (L*W*H) | |||
PACKING | 3.3Kg; 4pcs/14.2Kg/2.04CUFT |
Application
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Burn-in facility
- Digital broadcasting