Features
- 180 ~ 550Vac ultra wide input for 1-phase or 2-phase
- 32mm slim width
- 4.7KVac I/O high isolation(Reinforced isolation)
- Industrial control system
- Semiconductor fabrication equipment
- Factory automation
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- -30~+85°C ultra-wide operating temperature ( >+60°C derating)
- DC OK relay contact
- DC output voltage adjustable(+20%)
- 3 years warranty
Description
WDR-60 series is a 60W DIN rail power supply with ultra-wide AC input range. It is suitable to be mounted on TS-35/7.5 or TS-35/15 rails. Main features are as following: it can accept 180〜550Vac ultra-wide input voltage range for single phase or 2-phase system, easy to install DIN rail type, narrow width (32mm) in slim design, -30〜+85°C wide range operating temp, 4.7KVAC high isolation voltage, operation at 2000m altitude, adjustable output voltage (+20% max.), high efficiency, low ripple & noise, complete protections and so on. WDR-60 is compliant with BS EN/EN-61000-6-2 standard regarding immunity for industrial environments. It suitable for industrial automation, surveillance, telecommunication and more applications.
Mean Well Power Supply WDR-60 Series Model Encoding
Mean Well Power Supply WDR-60 Series Data Sheet Download
Specification
MODEL | WDR-60-5 | WDR-60-12 | WDR-60-24 | WDR-60-48 | |||
OUTPUT |
DC VOLTAGE | 5V | 12V | 24V | 48V | ||
RATED CURRENT | 10A | 5A | 2.5A | 1.25A | |||
CURRENT RANGE | 0 ~ 10A | 0 ~ 5A | 0 ~ 2.5A | 0 ~ 1.25A | |||
RATED POWER | 50W | 60W | 60W | 60W | |||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | |||
VOLTAGE ADJ. RANGE | 5 ~ 6V | 12 ~ 15V | 24 ~ 29V | 48 ~ 57V | |||
VOLTAGE TOLERANCE Note.3 | ±2% | ±1.5% | ±1.0% | ±1.0% | |||
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
LOAD REGULATION | ±1.5% | ±0.5% | ±0.5% | ±0.5% | |||
SETUP, RISE, HOLD UP TIME | 1000ms, 70ms, 20ms/400Vac 2000ms, 70ms, 10ms/230Vac at full load | ||||||
INPUT |
VOLTAGE RANGE Note.4 | 180 ~ 550Vac or 254 ~ 780Vdc | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
EFFICIENCY (Typ.) | 83.5% / 400Vac | 86.5% / 400Vac | 89% / 400Vac | 90.5% / 400Vac | |||
AC CURRENT | 0.4A/400Vac 0.7A/230Vac | ||||||
INRUSH CURRENT (max.) | COLD START 50A /400Vac 30A/230Vac | ||||||
LEAKAGE CURRENT | <2mA / 530Vac | ||||||
PROTECTION |
OVERLOAD | 105 ~ 135% rated output power | |||||
Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed
Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed |
|||||||
OVER VOLTAGE | 6.2 ~ 7.2V | 16 ~ 18V | 31 ~ 37V | 58 ~ 60.5V | |||
Protection type: Shut down o/p voltage, re-power on to recover | |||||||
OVER TEMPERATURE | Protection type: Shut down o/p voltage, re-power on to recover | ||||||
FUNCTION | DC OK SIGNAL | Relay contact rating(max.): 30V / 1A resistive | |||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +85℃ (Refer to “Derating Curve”) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP. | -40 ~ +85℃ | ||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 60℃) | ||||||
VIBRATION | Component: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting clip: Compliance to IEC60068-2-6 | ||||||
OPERATING ALTITUDE Note.5 | 2000 meters | ||||||
OVER VOLTAGE CATEGORY | Ⅱ; According to EN61558, EN50178, EN60664-1, EN62477-1, EN60204-1; altitude up to 2000 meters | ||||||
SAFETY & EMC (Note 7) |
SAFETY STANDARDS | UL61010, BS EN/EN61558-2-16, AS/NZS 62368.1, EAC TP TC 004 approved; design refer to GL and BS EN/EN60204-1(By request) | |||||
WITHSTAND VOLTAGE | I/P-O/P:4.7KVAC I/P-FG:2.5KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION |
Parameter | Standard | Test Level / Note | ||||
Conducted | BS EN/EN55032(CISPR32) | Class B | |||||
Radiated | BS EN/EN55032(CISPR32) | Class B | |||||
Harmonic Current | BS EN/EN61000-3-2 | Class A | |||||
Voltage Flicker | BS EN/EN61000-3-3 | ——- | |||||
EMC IMMUNITY |
BS EN/EN55035, BS EN/EN61000-6-2, BS EN/EN61204-3 | ||||||
Parameter | Standard | Test Level /Note | |||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air; Level 2, 4KV contact, criteria A | |||||
Radiated Susceptibility | BS EN/EN61000-4-3 | Level 3, 10V/m, criteria A | |||||
EFT Bursts | BS EN/EN61000-4-4 | Level 3, 2KV/5KHz, criteria A | |||||
Surge | BS EN/EN61000-4-5 | Level 4, 2KV/Line-Line, 4KV/Line-Earth, criteria A | |||||
Conducted | BS EN/EN61000-4-6 | Level 3, 10V, criteria A | |||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4, 30A/m, criteria A | |||||
Voltage Dips and interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
|||||
OTHERS |
MTBF | 1900.1K hrs min. Telcordia SR-332 (Bellcore); 313.7K hrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 32*125.2*102mm (W*H*D) | ||||||
PACKING | 0.45Kg; 28pcs/13.6Kg/1.24CUFT |