HBG-100 series
May 4, 2022HBG-160 series
May 4, 2022160W Constant Voltage + Constant Current LED Driver HBG-160P series
Features
- Constant Voltage + Constant Current mode output
- Circular shape PCB type design
- Built-in active PFC function
- Function options: output adjustable via potentiometer; 3 in 1 dimming; DALI
- Typical lifetime>50000 hours
- 5 years warranty
Data Sheet Download
Description
HBG-160P series is a 160W AC/DC PCB type LED driver featuring the circular shape design. It operates from 90~305VAC and offers the dual mode constant voltage and constant current output models with different rated voltage ranging between 36V and 60V. Thanks to the high efficiency up to 93.5%, with the fanless design, the entire series is able to operate for -40℃ ~ +45℃ under free air convection. HBG-160P is equipped with various function options, such as dimming methodology, so as to provide the optimal design flexibility for LED lighting system.
Model Encoding
Type | Function | Note |
A | Io adjustable through built-in potentiometer. | In Stock |
B | 3 in 1 dimming function (1~10Vdc, 10V PWM signal and resistance) | In Stock |
DA | DALI control technology. | In Stock |
Specification
MODEL | HBG-160P-36 | HBG-160P-48 | HBG-160P-60 | ||
OUTPUT |
DC VOLTAGE | 36V | 48V | 60V | |
CONSTANT CURRENT REGION Note.2 | 21.6 ~ 36V | 28.8 ~ 48V | 36 ~ 60V | ||
RATED CURRENT | 4.4A | 3.3A | 2.6A | ||
RATED POWER | Note.5 | 158.4W | 158.4W | 156W | |
RIPPLE & NOISE (max.) Note.3 | 300mVp-p | 300mVp-p | 300mVp-p | ||
CURRENT ADJ. RANGE |
Adjustable for A-Type only (via built-in potentiometer) | ||||
2.6 ~ 4.4A | 1.98 ~ 3.3A | 1.6 ~ 2.6A | |||
VOLTAGE TOLERANCE Note.4 | ±2.0% | ||||
LINE REGULATION | ±0.5% | ||||
LOAD REGULATION | ±1.0% | ||||
SETUP, RISE TIME Note.6 | 2500ms, 200ms / 115VAC 500ms, 200ms / 230VAC | ||||
HOLD UP TIME (Typ.) | 12ms/115VAC,230VAC | ||||
INPUT |
VOLTAGE RANGE |
Note.5 |
90 ~ 305VAC 127~417VDC
(Please refer to “STATIC CHARACTERISTIC” section) |
||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
POWER FACTOR |
PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section) |
||||
TOTAL HARMONIC DISTORTION |
THD< 20% (@load≧60%/115VC,230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section) |
||||
EFFICIENCY (Typ.) | Note.7 | 92% | 93% | 93.5% | |
AC CURRENT | 1.7A / 115VAC 0.78A / 230VAC 0.7A / 277VAC | ||||
INRUSH CURRENT(Typ.) | COLD START 65A (twidth=550μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | ||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC | ||||
LEAKAGE CURRENT | <0.75mA / 277VAC | ||||
NO LOAD / STANDBY POWER CONSUMPTION | Standby power consumption <0.5W for B/DA-Type A-Type please refer to Note. 9 | ||||
PROTECTION |
OVER CURRENT |
95 ~ 108% | |||
Constant current limiting, recovers automatically after fault condition is removed | |||||
OVER VOLTAGE |
41 ~ 47V | 54 ~ 62V | 65 ~ 75V | ||
Protection type: Shut down o/p voltage with auto-recovery or re-power on to recovery | |||||
OVER TEMPERATURE Note.13 | Shut down o/p voltage, recovers automatically after temperature goes down | ||||
ENVIRONMENT |
WORKING TEMP. | Ta=-40 ~ +45℃ (Please refer to “OUTPUT LOAD vs TEMPERATURE” section) | |||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 45℃) | ||||
VIBRATION | 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes | ||||
SAFETY & EMC |
SAFETY STANDARDS |
UL8750, CSA C22.2 No.250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13, BS EN/EN62384, GB19510.1, GB19510.14, EAC TP TC 004 approved | |||
DALI STANDARDS | Compliance to IEC62386-101, 102, 207 for DA-Type only | ||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||
EMC EMISSION | Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load ≧60%); BS EN/EN61000-3-3, GB17743, GB17625.1, EAC TP TC 020 | ||||
EMC IMMUNITY |
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level (surge immunity: Line-Earth:4KV, Line-Line:2KV), EAC TP TC 020 | ||||
OTHERS |
MTBF | 195.5Khrs min. MIL-HDBK-217F (25℃) | |||
DIMENSION | Refer to mechanical specification | ||||
PACKING | 0.4Kg; 36pcs/15.4Kg/1.35CUFT |
Application
- LED bay lighting
- LED down lighting
- LED spot lighting
- LED mining lighting
- LED stage lighting