HBG-160P series
May 4, 2022HBG-200 series
May 4, 2022160W Constant Voltage + Constant Current LED Driver HBG-160 series
Features
- Constant Voltage + Constant Current mode output
- Circular metal housing with class Ⅰ design
- Built-in active PFC function
- IP67 / IP65 rating for indoor or outdoor installations
- Function options: output adjustable via potentiometer; 3 in 1 dimming; DALI
- Typical lifetime>50000 hours
- 5 years warranty
Data Sheet Download
Description
HBG-160 series is a 160W AC/DC LED driver featuring the circular shape design. It operates from 90~305VAC and offers the dual modes constant voltage and constant current output models with different rated voltage between 24Vand 60V. Thanks to the high efficiency up to 93.5%, with the fanless design, the entire series is able to operate for -40℃ ~ +85℃ case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. HBG-160 is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Model Encoding
Type | IP Level | Function | Note |
Blank | IP67 | Io fixed. | In Stock |
A | IP65 | Io adjustable through built-in potentiometer. | In Stock |
B | IP67 | 3 in 1 dimming function (1~10Vdc, 10V PWM signal and resistance) | In Stock |
AB | IP65 | Io adjustable through built-in potentiometer with 3 in 1 dimming function | In Stock |
DA | IP67 | DALI control technology. | In Stock |
Specification
MODEL | HBG-160-24 | HBG-160-36 | HBG-160-48 | HBG-160-60 | ||
OUTPUT |
DC VOLTAGE | 24V | 36V | 48V | 60V | |
CONSTANT CURRENT REGION Note.2 | 14.4 ~ 24V | 21.6 ~ 36V | 28.8 ~ 48V | 36 ~ 60V | ||
RATED CURRENT | 6.5A | 4.4A | 3.3A | 2.6A | ||
RATED POWER | 156W | 158.4W | 158.4W | 156W | ||
RIPPLE & NOISE (max.) Note.3 | 200mVp-p | 300mVp-p | 300mVp-p | 300mVp-p | ||
CURRENT ADJ. RANGE |
Adjustable for A/AB-Type (via built-in potentiometer) | |||||
3.9 ~ 6.5A | 2.6 ~ 4.4A | 1.98 ~ 3.3A | 1.6 ~ 2.6A | |||
VOLTAGE TOLERANCE Note.4 | ±2.0% | |||||
LINE REGULATION | ±0.5% | |||||
LOAD REGULATION | ±1.0% | |||||
SETUP, RISE TIME | Note.6 | 2500ms, 200ms / 115VAC 500ms, 200ms / 230VAC | ||||
HOLD UP TIME (Typ.) | 12ms /115VAC, 230VAC | |||||
INPUT |
VOLTAGE RANGE |
Note.5 |
90 ~ 305VAC 127~417VDC
(Please refer to “STATIC CHARACTERISTIC” section) |
|||
FREQUENCY RANGE | 47 ~ 63Hz | |||||
POWER FACTOR |
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section) |
|||||
TOTAL HARMONIC DISTORTION |
THD< 20% (@load≧60%/115VC,230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section) |
|||||
EFFICIENCY (Typ.) | Note.7 | 92% | 92% | 93% | 93.5% | |
AC CURRENT (Typ.) | 1.7A / 115VAC 0.78A / 230VAC 0.7A / 277VAC | |||||
INRUSH CURRENT (Typ.) | COLD START 65A (twidth=550μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | |||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC | |||||
LEAKAGE CURRENT | <0.75mA / 277VAC | |||||
NO LOAD / STANDBY POWER CONSUMPTION | Standby power consumption <0.5W for B/AB/DA-Type Blank/A-Type please refer to Note.9 | |||||
PROTECTION |
OVER CURRENT | 95 ~ 108% | ||||
Constant current limiting, recovers automatically after fault condition is removed | ||||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |||||
OVER VOLTAGE |
28 ~ 34V | 41 ~ 47V | 54 ~ 62V | 65 ~ 75V | ||
Shut down o/p voltage with auto-recovery or re-power on to recovery | ||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |||||
ENVIRONMENT |
WORKING TEMP. | Tcase=-40 ~ +85℃ (Please refer to “OUTPUT LOAD vs TEMPERATURE” section) | ||||
MAX. CASE TEMP. | Tcase=+85℃ | |||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | |||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||
SAFETY & EMC |
SAFETY STANDARDS | UL8750(type”HL”),CSA C22.2 No.250.13-12, TUV BS EN/EN61347-1,BS EN/EN61347-2-13; BIS IS15885(for 36A,48A,48B,60A, 60DA only), EAC TP TC 004, GB19510.1,GB19510.14, IP65 or IP67 approved | ||||
DALI STANDARDS | Compliance to IEC62386-101, 102, 207 for DA-Type only | |||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||
EMC EMISSION | Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load≧60%); BS EN/EN61000-3-3, GB17743 and GB17625.1, EAC TP TC 020 | |||||
EMC IMMUNITY |
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level (surge immunity: Line-Earth:4KV, Line-Line:2KV), EAC TP TC 020 | |||||
OTHERS |
MTBF | 783.1K hrs min. Telcordia SR-332 (Bellcore); 252.3Khrs min. MIL-HDBK-217F (25℃) | ||||
DIMENSION | ψ151.68mm *66.5mm (D * H) | |||||
PACKING | 1.53Kg; 8pcs/13.8Kg/1.37CUFT |
Application
- LED bay lighting
- LED stage lighting
- LED spot lighting
- Type “HL” for use in Class I, Division 2 hazardous (Classified)