GST25A series
August 22, 2024MW Mean Well Meanwell 18W AC-DC Reliable Green Industrial Adaptor GST18A Series
Features
- Global certificates
- Universal AC input / Full range
- 3 pole AC inlet IEC320-C14,Class I power unit
- No load power consumption< 0.075W
- Energy efficiency Level VI
- Comply with EISA 2007/DoE,NRCan,Korea K-MEPS, AU/NZ MEPS.EU ErP and CoC Version 5
- Protections: Short circuit / Overload / Over voltage
- Fully enclosed plastic case
- Pass LPS
- -30-+70℃ wide range working temperature
- LED indicator for power on
Description
The Mean Well GST18A series is a highly reliable, 18W desktop style single-output green adaptor series designed to connect electrical equipment externally. It is a class I power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopts an input range from 85VAC to 264VAC.
The GST18A series supplies different models with output voltages ranging between 5VDC and 48VDC (GST18A05-P1J, GST18A07-P1J, GST18A09-P1J, GST18A12-P1J, GST18A15-P1J, GST18A18-P1J, GST18A24-P1J, GST18A28-P1J, GST18A48-P1J) to satisfy the demands of various consumer electronic devices.
Mean Well Industrial Desktop Adaptor GST18A Series Model Encoding
Mean Well Industrial Desktop Adaptor GST18A Series Data Sheet Download
Specification
ORDER NO. | GST18A05-P1J | GST18A07-P1J | GST18A09-P1J | GST18A12-P1J | GST18A15-P1J | GST18A18-P1J | GST18A24-P1J | GST18A28-P1J | GST18A48-P1J | |||
OUTPUT |
SAFETY MODEL NO. | GST18A05 | GST18A07 | GST18A09 | GST18A12 | GST18A15 | GST18A18 | GST18A24 | GST18A28 | GST18A48 | ||
DC VOLTAGE Note.2 | 5V | 7.5V | 9V | 12V | 15V | 18V | 24V | 28V | 48V | |||
RATED CURRENT | 3.0A | 2.0A | 2.0A | 1.50A | 1.20A | 1.0A | 0.75A | 0.64A | 0.375A | |||
CURRENT RANGE | 0 ~ 3.0A | 0 ~ 2.0A | 0 ~2.0A | 0 ~ 1.50A | 0 ~ 1.20A | 0 ~ 1.0A | 0 ~ 0.75A | 0 ~ 0.64A | 0 ~ 0.375A | |||
RATED POWER (max.) | 15W | 15W | 18W | 18W | 18W | 18W | 18W | 18W | 18W | |||
RIPPLE & NOISE (max.) Note.3 | 80mVp-p | 80mVp-p | 80mVp-p | 80mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |||
VOLTAGE TOLERANCE Note.4 | ±5.0% | ±5.0% | ±5.0% | ±3.0% | ±3.0% | ±3.0% | ±2.0% | ±2.0% | ±2.0% | |||
LINE REGULATION Note.5 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
LOAD REGULATION Note.6 | ±5.0% | ±5.0% | ±5.0% | ±3.0% | ±3.0% | ±3.0% | ±2.0% | ±2.0% | ±2.0% | |||
SETUP, RISE, HOLD UP TIME | 1000ms, 30ms, 50ms/230VAC 1500ms, 30ms, 15ms/115VAC at full load | |||||||||||
INPUT |
VOLTAGE RANGE Note.7 | 85 ~ 264VAC | ||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||||
EFFICIENCY (Typ.) | 81% | 85% | 85% | 86% | 87% | 88% | 88% | 88.5% | 89% | |||
AC CURRENT | 0.5A / 115VAC 0.3A / 230VAC | |||||||||||
INRUSH CURRENT (max.) | Cold start 35A / 115VAC 65A / 230VAC | |||||||||||
LEAKAGE CURRENT (max.) | 0.75mA / 240VAC | |||||||||||
PROTECTION |
OVERLOAD |
110 ~ 150% rated output power | ||||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||||
OVER VOLTAGE |
110 ~ 140% rated output voltage | |||||||||||
Protection type: Clamp by zener diode, output short | ||||||||||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | ||||||||||
WORKING HUMIDITY | 20% ~ 90% RH non-condensing | |||||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||||||
TEMP. COEFFICIENT | ±0.03% / ℃ (0 ~ 50℃) | |||||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||||||||
SAFETY & EMC (Note. 9) |
SAFETY STANDARDS Note. 8 | UL62368-1, CSA C22.2 No.62368-1, TUV BS EN/EN62368-1, BSMI CNS 14336-1 , CCC GB4943.1, PSE J62368-1, AS/NZS 60950.1,BIS IS13252, KC K60950-1, EAC TP TC 004 approved; SIRIM MS IEC62368-1 (optional) approved | ||||||||||
WITHSTAND VOLTAGE | I/P-O/P:4242VDC, I/P-FG:2121VDC | |||||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||||||
EMC EMISSION |
Parameter | Standard | Test Level / Note | |||||||||
Conducted emission |
BS EN/EN55032(CISPR32), FCC PART 15/CISPR22 CAN ICES-3(B)/NMB-3(B), CNS13438, GB17625.1 EAC TP TC 020, MSIP KN32 |
Class B |
||||||||||
Radiated emission |
BS EN/EN55032(CISPR32), FCC PART 15/CISPR22 CAN ICES-3(B)/NMB-3(B), CNS13438, GB17625.1 EAC TP TC 020, MSIP KN32 |
Class B |
||||||||||
Harmonic current | BS EN/EN61000-3-2, GB9254 | Class A | ||||||||||
Voltage flicker | BS EN/EN61000-3-3 | ——- | ||||||||||
EMC IMMUNITY |
BS EN/EN55035 | |||||||||||
Parameter | Standard | Test Level /Note | ||||||||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air; Level 2, 4KV contact | ||||||||||
RF field susceptibility | BS EN/EN61000-4-3 | Level 2, 3V/m | ||||||||||
EFT bursts | BS EN/EN61000-4-4 | Level 2, 1KV | ||||||||||
Surge susceptibility | BS EN/EN61000-4-5 | Level 3, 1KV/Line-Line, 2KV/Line-FG | ||||||||||
Conducted susceptibility | BS EN/EN61000-4-6 | Level 2, 3V | ||||||||||
Magnetic field immunity | BS EN/EN61000-4-8 | Level 2, 3A/m | ||||||||||
Voltage dips, interruption | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
||||||||||
OTHERS |
MTBF | 3879.7K hrs min. Telcordia SR-332 (Bellcore); 668.4K hrs min. MIL-HDBK-217F (25℃) | ||||||||||
DIMENSION | 93*54*36mm (L*W*H) | |||||||||||
PACKING | 209g; 60pcs/13.5Kg/1.02CUFT | |||||||||||
CONNECTOR |
PLUG | See page 4~5; Other type available by customer requested | ||||||||||
CABLE | See page 4~5; Other type available by customer requested |
Applications
- Consumer electronic devices
- Telecommunication devices
- Office facilities
- Industrial equipments