LRS-50 series
June 28, 2022LRS-100 series
June 28, 2022MW Mean Well Meanwell 75W Single Output Switching Power Supply LRS-75 series
Features
- Universal AC input / Full range
- Withstand 300VAC surge input for 5 second
- No load power consumption<0.3W
- Miniature size and 1U low profile
- High operating temperature up to 70℃
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Compliance to IEC/BS EN/EN 60335-1(PD3) and IEC/BS EN/EN61558-1, -2-16 for household appliances
- Operating altitude up to 5000 meters
- Withstand 5G vibration test
- High efficiency, long life and high reliability
- LED indicator for power on
- Over voltage category III
- 100% full load burn-in test
- 3 years warranty
Mean Well LRS-75 Series Data Sheet Download
Description
Mean Well LRS-75 series is a 75W single-output enclosed type power supply with 30mm of low profile design. Adopting the full range 85~264VAC input, the entire series provides an output voltage line of 5V(Model No.: LRS-75-5), 12V(Model No.: LRS-75-12), 15V(Model No.: LRS-75-15), 24V(Model No.: LRS-75-24), 36V and(Model No.: LRS-75-36) 48V(Model No.: LRS-75-48).
In addition to the high efficiency up to 91.5%, the design of metallic mesh case enhances the heat dissipation of LRS-75 that the whole series operates from -30℃ through 70℃ under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.3W), it allows the end system to easily meet the worldwide energy requirement. LRS-75 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as TUV BS EN/EN62368-1, BS EN/EN60335-1,BS EN/EN61558-1/-2-16, UL62368-1 and GB4943. LRS-75 series serves as a high price-to-performance power supply solution for various industrial applications.
In LRS Family, there are LRS-35 series, LRS-50 series, LRS-75 series, LRS-100 series, LRS-150F series, LRS-150 series, LRS-200 series, LRS-350 series, LRS-450 series, LRS-600 series.
Mean Well LRS-75 Series Model Encoding
Specification
MODEL | LRS-75-5 | LRS-75-12 | LRS-75-15 | LRS-75-24 | LRS-75-36 | LRS-75-48 | |
OUTPUT |
DC VOLTAGE | 5V | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 14A | 6A | 5A | 3.2A | 2.1A | 1.6A | |
CURRENT RANGE | 0 ~ 14A | 0 ~ 6A | 0 ~ 5A | 0 ~ 3.2A | 0 ~ 2.1A | 0 ~ 1.6A | |
RATED POWER | 70W | 72W | 75W | 76.8W | 75.6W | 76.8W | |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 4.5 ~ 5.5V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 500ms, 30ms/230VAC 500ms,30ms/115VAC at full load | ||||||
HOLD UP TIME (Typ.) | 60ms/230VAC 12ms/115VAC at full load | ||||||
INPUT |
VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 373VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
EFFICIENCY (Typ.) | 86.5% | 89% | 89% | 90% | 91.5% | 91.5% | |
AC CURRENT (Typ.) | 1.4A/115VAC 0.85A/230VAC | ||||||
INRUSH CURRENT (Typ.) | COLD START 65A/230VAC | ||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | ||||||
PROTECTION |
OVER LOAD |
110 ~ 150% rated output power | |||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE |
5.75 ~ 6.75V | 13.8 ~ 16.2V | 18.75 ~ 21.75V | 28.8 ~ 33.6V | 41.4 ~ 48.6V | 55.2 ~ 64.8V | |
Protection type: Shut down o/p voltage, re-power on to recover | |||||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
OVER VOLTAGE CATEGORY |
Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1;
altitude up to 2000 meters |
||||||
SAFETY & EMC (Note 8) |
SAFETY STANDARDS |
UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, CCC GB4943.1, BSMI CNS14336-1, EAC TP TC 004, AS/NZS 62368.1(by CB), KC K60950-1(for LRS-75-12/24 only), BIS IS13252(Part1):
2010/IEC 60950-1: 2005 approved |
|||||
WITHSTAND VOLTAGE | I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3, GB/T 9254, BSMI CNS13438, EAC TP TC 020,KC KN32,KN35(for LRS-75-12/24 only) | ||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, criteria A, EAC TP TC 020, KC KN32,KN35(for LRS-75-12/24 only) | ||||||
OTHERS |
MTBF | 681.2K hrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 99*97*30mm (L*W*H) | ||||||
PACKING | 0.25Kg; 45pcs/ 12.25Kg/ 0.77CUFT |
Application
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
- Household appliances
Mean Well Enclosed Power Supply LRS-75 Series Unboxing
What you see in this video is what you get for the model LRS-75-24.
Mean Well LRS-75 Series Video Show