LRS-200 series
June 28, 2022LRS-450 series
June 28, 2022MW Mean Well Meanwell 350W Single Output Switching Power Supply LRS-350 series
Features
- AC input range selectable by switch
- Withstand 300VAC surge input for 5 second
- No load power consumption<0.75W
- 1U low profile
- High operating temperature up to 70℃
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Forced air cooling by built-in DC fan
- Built-in cooling Fan ON-OFF control
- Operating altitude up to 5000 meters
- Withstand 5G vibration test
- High efficiency, long life and high reliability
- LED indicator for power on
- 100% full load burn-in test
- 3 years warranty
Mean Well LRS-350 Series Data Sheet Download
Description
Mean Well LRS-350 series is a 350W single-output enclosed type power supply with 30mm of low profile design. Adopting the input of 115VAC or 230VAC (select by switch), the entire series provides an output voltage line of 3.3V(Model No.: LRS-350-3.3), 4.2V(Model No.: LRS-350-4.2), 5V(Model No.: LRS-350-5), 12V(Model No.: LRS-350-12), 15V(Model No.: LRS-350-15), 24V(Model No.: LRS-350-24), 36V(Model No.: LRS-350-36) and 48V(Model No.: LRS-350-48).
In addition to the high efficiency up to 89%, with the built-in long life fan LRS-350 can work under -25~+70℃ with full load. Delivering an extremely low no load power consumption (less than 0.75W), it allows the end system to easily meet the worldwide energy requirement. LRS-350 has the complete protection functions and 5G anti-vibration capability; it is complied with the international safety regulations such as IEC/UL 62368-1. LRS-350 series serves as a high price-to-performance power supply solution for various industrial applications.
In LRS Family, there are LRS-35 series, LRS-50 series, LRS-75 series, LRS-100 series, LRS-150F series, LRS-150 series, LRS-200 series, LRS-350 series, LRS-450 series, LRS-600 series.
Mean Well LRS-350 Series Model Encoding
Specification
MODEL | LRS-350-3.3 | LRS-350-4.2 | LRS-350-5 | LRS-350-12 | LRS-350-15 | LRS-350-24 | LRS-350-36 | LRS-350-48 | |
OUTPUT |
DC VOLTAGE | 3.3V | 4.2V | 5V | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 60A | 60A | 60A | 29A | 23.2A | 14.6A | 9.7A | 7.3A | |
CURRENT RANGE | 0 ~ 60A | 0 ~ 60A | 0 ~ 60A | 0 ~ 29A | 0 ~ 23.2A | 0 ~ 14.6A | 0 ~ 9.7A | 0 ~ 7.3A | |
RATED POWER | 198W | 252W | 300W | 348W | 348W | 350.4W | 349.2W | 350.4W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 2.97 ~ 3.6V | 3.6 ~ 4.4V | 4.5 ~ 5.5V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±4.0% | ±4.0% | ±3.0% | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±2.5% | ±2.5% | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1300ms, 50ms/230VAC 1300ms,50ms/115VAC at full load | ||||||||
HOLD UP TIME (Typ.) | 16ms/230VAC 12ms/115VAC at full load | ||||||||
INPUT |
VOLTAGE RANGE | 90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (switch on 230VAC) | |||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||
EFFICIENCY (Typ.) | 79.5% | 81.5% | 83.5% | 85% | 86% | 88% | 88.5% | 89% | |
AC CURRENT (Typ.) | 6.8A/115VAC 3.4A/230VAC | ||||||||
INRUSH CURRENT (Typ.) | 60A/115VAC 60A/230VAC | ||||||||
LEAKAGE CURRENT | <2mA / 240VAC | ||||||||
PROTECTION |
OVER LOAD |
110 ~ 140% rated output power | |||||||
3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover. | |||||||||
OVER VOLTAGE |
3.8 ~ 4.45V | 4.6 ~ 5.4V | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 18 ~ 21V | 28.8 ~ 33.6V | 41.4 ~ 46.8V | 55.2 ~ 64.8V | |
3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover. | |||||||||
OVER TEMPERATURE | 3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover. | ||||||||
FUNCTION | FAN ON/OFF CONTROL
(Typ.) |
RTH3≧50℃ FAN ON, ≦40℃ FAN OFF | |||||||
ENVIRONMENT |
WORKING TEMP. | -25 ~ +70℃ (Refer to “Derating Curve”) | |||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||||
SAFETY |
SAFETY STANDARDS | IEC/UL 62368-1, BSMI CNS14336-1, BS EN/EN60335-1,EAC TP TC 004,KC K60950-1(for LRS-350-12/24 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005, AS/NZS62368.1 approved; Design refer to BS EN/EN62368-1 | |||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH | ||||||||
EMC EMISSION | Compliance to BSMI CNS13438, EAC TP TC 020,KC KN32,KN35(for LRS-350-12/24 only) | ||||||||
EMC IMMUNITY | Compliance to EAC TP TC 020,KC KN32,KN35(for LRS-350-12/24 only) | ||||||||
OTHERS |
MTBF | 327.9K hrs min. MIL-HDBK-217F (25℃) | |||||||
DIMENSION | 215*115*30mm (L*W*H) | ||||||||
PACKING | 0.76Kg; 15pcs/12.4Kg/0.78CUFT |
Application
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
Mean Well Enclosed Power Supply LRS-350 Series Unboxing
What you see in this video is what you get for the model LRS-350-24.
Mean Well Enclosed Power Supply LRS-350 Series Video Show
The model in this video is LRS-350-24 from Mean Well enclosed power supply LRS-350 series.