MDR-40 series
September 16, 2023MDR-100 series
September 16, 2023MW Mean Well Meanwell 60W Single Output Switching Power Supply DIN Rail MDR-60 Series
Features
- Universal AC input/Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- Class I, Div 2 Hazardous Locations T4
- LED indicator for power on
- DC OK relay contact
- No load power consumption<0.75W
- 100% full load burn-in test
- 3 years warranty
Description
The MDR-60 series is a line of high-quality DIN rail power supplies manufactured by Mean Well. These power supplies are designed to deliver reliable and efficient power for various industrial applications. With a power output of 60W, they provide ample power for demanding systems.
The MDR-60 series features a compact and slim design, making it easy to install on DIN rails within control panels or cabinets. It offers a single output with voltage options ranging from 5V to 48V with the model No. MDR-60-5, MDR-60-12, MDR-60-24 and MDR-60-48, allowing flexibility to meet different system requirements. The power supplies are equipped with a universal AC input, enabling them to be used worldwide.
These power supplies are built with robust components and undergo rigorous testing to ensure their reliability and durability. They have a wide operating temperature range, allowing them to function effectively in challenging environments. Additionally, the MDR-60 series includes built-in protections against overvoltage, overload, and short circuits, safeguarding connected devices from potential damage.
The MDR-60 series complies with international safety standards and regulations, providing peace of mind in terms of safety and quality. They have high efficiency and low energy consumption, contributing to energy savings and reducing operational costs.
In summary, the 60W Mean Well Single Output DIN Rail Power Supply MDR-60 series offers a reliable and efficient power solution for industrial applications. With its compact design, wide voltage range, and built-in protections, it provides stable and safe power delivery for various systems and installations.
Mean Well Power Supply MDR-60 Series Data Sheet Download
Specification
MODEL | MDR-60-5 | MDR-60-12 | MDR-60-24 | MDR-60-48 | |
OUTPUT |
DC VOLTAGE | 5V | 12V | 24V | 48V |
RATED CURRENT | 10A | 5A | 2.5A | 1.25A | |
CURRENT RANGE | 0 ~ 10A | 0 ~ 5A | 0 ~ 2.5A | 0 ~ 1.25A | |
RATED POWER | 50W | 60W | 60W | 60W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 5 ~ 6V | 12 ~ 15V | 24 ~ 30V | 48 ~ 56V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±1.5% | ±1.0% | ±1.0% | ±1.0% | |
SETUP, RISE TIME Note.5 | 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load | ||||
HOLD UP TIME (Typ.) | 50ms/230VAC 20ms/115VAC at full load | ||||
INPUT |
VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY (Typ.) | 78% | 86% | 88% | 87% | |
AC CURRENT (Typ.) | 1.8A/115VAC 1A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 30A/115VAC 60A/230VAC | ||||
LEAKAGE CURRENT | <1mA / 240VAC | ||||
PROTECTION |
OVERLOAD |
105 ~ 150% rated output power | |||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | |||||
OVER VOLTAGE |
6.25 ~ 7.25V | 15.6 ~ 18V | 31.2 ~ 36V | 57.6 ~ 64.8V | |
Protection type: Shut down o/p voltage, re-power on to recover | |||||
FUNCTION | DC OK SIGNAL | Relay contact rating(max.): 30V/1A resistive | |||
ENVIRONMENT |
WORKING TEMP. | -20 ~ +70℃ (Refer to “Derating Curve”) | |||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||
VIBRATION | Component: 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | ||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS | Ul508, UL62368-1, TUV BS EN/EN62368-1, Class I, Div. 2 Group A, B, C, D Hazardous Locations T4, EAC TP TC 004, BSMI CNS14336-1, AS/NZS 60950.1, IS13252(Part1)/IEC60950-1(except 48V) approved | |||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH | ||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2, -3, EAC TP TC 020, CNS13438 Class B | ||||
EMC IMMUNITY |
Compliance to BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11, BS EN/EN55035, BS EN/EN61000-6-2, BS EN/EN61204-3, heavy industry level, EAC TP TC 020 | ||||
OTHERS |
MTBF | 2355.2K hrs min. Telcordia SR-332 (Bellcore); 489.9K hrs min. MIL-HDBK-217F (25℃) | |||
DIMENSION | 40*90*100mm (W*H*D) | ||||
PACKING | 0.33Kg; 42pcs/14.8Kg/0.82CUFT |
Mean Well DIN Rail Power Supply MDR-60 Series Unboxing
What you see in this video is what you get for the model MDR-60-24.
Mean Well Power Supply MDR-60 Series Video Show
The model in this video is MDR-60-24 from Mean Well DIN Rail power supply MDR-60 series.