SDR-240 series
September 22, 2023SDR-480 series
September 22, 2023MW Mean Well Meanwell 480W Single Output Industrial Switching Power Supply DIN Rail with PFC and Parallel Function SDR-480P Series
Features
- Current sharing up to 3840W(7+1)
- High efficiency 94% and low power dissipation
- 150% peak load capability
- Built-in active PFC function, PF>0.94
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Built-in constant current limiting circuit
- Can be installed on DIN rail TS-35/7.5 or 15
- UL 508(industrial control equipment)approved
- BS EN/EN61000-6-2(BS EN/EN50082-2) industrial immunity level
- Built-in DC OK relay contact
- 100% full load burn-in test
- 3 years warranty
Description
Mean Well Power Supply SDR-480P Series Data Sheet Download
Specification
MODEL | SDR-480P-24 | SDR-480P-48 | |
OUTPUT |
DC VOLTAGE | 24V | 48V |
RATED CURRENT | 20A | 10A | |
CURRENT RANGE | 0 ~ 20A | 0 ~ 10A | |
RATED POWER | 480W | 480W | |
PEAK CURRENT | 30A | 15A | |
PEAK POWER Note.6 | 720W (3sec.) | ||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | |
VOLTAGE ADJ. RANGE | 24 ~ 28V | 48 ~ 55V | |
VOLTAGE TOLERANCE Note.3 | ±1.2% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | |
SETUP, RISE TIME | 1500ms, 150ms/230VAC 3000ms, 150ms/115VAC at full load | ||
HOLD UP TIME (Typ.) | 14ms/230VAC at full load | ||
INPUT |
VOLTAGE RANGE Note.7 | 90 ~ 264VAC 127 ~ 370VDC | |
FREQUENCY RANGE | 47 ~ 63Hz | ||
POWER FACTOR (Typ.) | 0.94/230VAC 0.99/115VAC at full load | ||
EFFICIENCY (Typ.) | 94% | ||
AC CURRENT (Typ.) | 5A/115VAC 2.5A/230VAC | ||
INRUSH CURRENT (Typ.) | 40A/115VAC 80A/230VAC | ||
LEAKAGE CURRENT | <0.6mA / 240VAC | ||
PROTECTION |
OVERLOAD |
Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage with auto-recovery | |
>150% rated power, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds | |||
OVER VOLTAGE |
29 ~ 33V | 56 ~ 65V | |
Protection type: Shut down o/p voltage with auto-recovery or re-power on to recovery | |||
OVER TEMPERATURE |
105℃±5℃ (TSW: detect on heatsink of power switch) | ||
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down | |||
FUNCTION |
DC OK REALY CONTACT RATINGS (max.) | 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load | |
CURRENT SHARING | Please see the Function Manual | ||
ENVIRONMENT |
WORKING TEMP. Note.5 | -25 ~ +70℃ (Refer to “Derating Curve”) | |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | ||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS | UL508, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004, BSMI CNS14336-1 approved | |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC | ||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH | ||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2, -3, EAC TP TC 020, CNS13438 | ||
EMC IMMUNITY |
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN61204-3,
heavy industry level, EAC TP TC 020, SEMI F47 approved |
||
OTHERS |
MTBF | 969.8K hrs min. Telcordia SR-332 (Bellcore); 118.6K hrs min. MIL-HDBK-217F (25℃) | |
DIMENSION | 85.5*125.2*128.5mm (W*H*D) | ||
PACKING | 1.6Kg; 8pcs/13.8Kg/0.9CUFT |
Mean Well Power Supply SDR-480P Series Unboxing
What you see in this video is what you get for the model SDR-480P-24.
Mean Well Power Supply SDR-480P Series Video Show
[icon type=”icon-lamp”The model in this video is SDR-480P-24 from Mean Well enclosed power supply SDR-480P series.