HRPG-1000 series
June 26, 2023HRP-300N3 series
June 27, 2023MW Mean Well Meanwell 150W Ultra-High Peak Power Supply HRP-150N3 series
Features
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
300% peak power capability
Built-in constant current limiting circuit
Fanless design, Cooling by free air convection
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in remote sense function
Withstand 5G vibration
Oprating altitude up to 5000 meters(Note.5)
Output votage adjustable ±15%(Avg.)
1U low profile 38mm
5 years warranty
Mean Well Ultra-high Peak Power Supply HRP-150N3 Series Data Sheet Download
Description
Mean Well ultra-high peak power supply HRP-150N3 series is a 150W single output AC/DC ultra-high peak power supply. This series operates at 85~264VAe input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by free air convection, working for the temperature up to 70℃ without cover. Moreover, MW HRP-150N3 can provide 300% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.
Model Encoding
Specification
MODEL | HRP-150N3-12 | HRP-150N3-24 | HRP-150N3-36 | HRP-150N3-48 | |||
OUTPUT |
DC VOLTAGE | 12V | 24V | 36V | 48V | ||
RATED CURRENT | 13A | 6.5A | 4.3A | 3.3A | |||
CURRENT RANGE | 0 ~ 13A | 0 ~ 6.5A | 0 ~ 4.3A | 0 ~ 3.3A | |||
RATED POWER | 156W | 156W | 154.8W | 158.4W | |||
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | 150mVp-p | 200mVp-p | 240mVp-p | |||
VOLTAGE ADJ. RANGE | 10.2 ~ 13.8V | 21.6 ~ 28.8V | 28.8 ~ 39.6V | 40.8 ~ 55.2V | |||
VOLTAGE TOLERANCE Note.3 | ±1.5% | ±1.5% | ±1.5% | ±1.5% | |||
LINE REGULATION | ±0.3% | ±0.2% | ±0.2% | ±0.2% | |||
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
SETUP, RISE TIME | 3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load | ||||||
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC at full load | ||||||
INPUT |
VOLTAGE RANGE Note.4 | 85 ~ 264VAC 120 ~ 370VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
POWER FACTOR (Typ.) | PF>0.95/230VAC PF>0.98/115VAC at full load | ||||||
EFFICIENCY (Typ.) | 88% | 88% | 89% | 89% | |||
AC CURRENT (Typ.) | 1.7A/115VAC 0.9A/230VAC | ||||||
INRUSH CURRENT (Typ.) | 35A/115VAC 70A/230VAC | ||||||
LEAKAGE CURRENT | <1mA / 240VAC | ||||||
PROTECTION |
OVERLOAD |
Output power >105% rated for more than 5 seconds then shut down o/p voltage, re-power on to recover | |||||
Constant current limiting for output power >330% rated for more than 5 seconds and then shut down o/p voltage, re-power on to recover | |||||||
OVER VOLTAGE |
14.4 ~ 16.8V | 30 ~ 34.8V | 41.4 ~ 48.6V | 57.6 ~ 67.2V | |||
Protection type: Shut down o/p voltage, re-power on to recover | |||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||||||
ENVIRONMENT |
WORKING TEMP. | -40 ~ +70℃ (Refer to “Derating Curve”) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -50 ~ +85℃, 10 ~ 95% RH non-condensing | ||||||
TEMP. COEFFICIENT | ±0.04%/℃ (0 ~ 50℃) | ||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
OPERATING ALTITUDE Note.5 | 5000 meters | ||||||
SAFETY & EMC (Note 6) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, AS/NZS 62368.1 approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION |
Parameter | Standard | Test Level / Note | ||||
Conducted | BS EN/EN55032 | Class B | |||||
Radiated | BS EN/EN55032 | Class B | |||||
Harmonic current | BS EN/EN61000-3-2 | Class A | |||||
Voltage Flicker | BS EN/EN61000-3-3 | —– | |||||
EMC IMMUNITY |
BS EN/EN55035, BS EN/EN61000-6-2(BS EN/EN50082-2) | ||||||
Parameter | Standard | Test Level / Note | |||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air; Level 2, 4KV contact | |||||
RF field | BS EN/EN61000-4-3 | Level 3, 10V/m | |||||
EFT/ Burst | BS EN/EN61000-4-4 | Level 3, 2KV | |||||
Surge | BS EN/EN61000-4-5 | Level 4, 4KV/Line-FG; 2KV/Line-Line | |||||
Conducted | BS EN/EN61000-4-6 | Level 3, 10V | |||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4, 30A/m | |||||
Voltage Dips and Interruptions |
BS EN/EN61000-4-11 |
95% dip 0.5 periods, 30% dip 25 periods,
95% interruptions 250 periods |
|||||
OTHERS |
MTBF | 1706.0K hrs min. Telcordia TR/SR-332 (Bellcore); 222.8K hrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 159*97*38mm (L*W*H) | ||||||
PACKING | 0.54Kg; 24pcs/12.96Kg/0.9CUFT |
Application
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Diagnostic or biological facilities
- Test or measurement systems
- Telecommunication equipment