RSP-1000 series
June 30, 2023RSP-1600 series
June 30, 2023MW Mean Well Meanwell 1500W Single Output with PFC Fucntion Switching Power Supply RSP-1500 series
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 91%
- Forced air cooling by built-in DC fan
- Output voltage programmable
- Active current sharing up to 6000W
- Built-in remote ON-OFF control / remote sense / auxiliary power / DC OK signal
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Optional conformal coating
- 5 years warranty
Mean Well Enclosed Switching Power Supply RSP-1500 Series Data Sheet Download
Description
Mean Well RSP-1500 is a 1.5KW single output enclosed type AC/DC power supply with PFC function. This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan working for the temperature up to 70℃. Moreover, RSP-1500 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.
Mean Well Enclosed Switching Power Supply RSP-1500 Series Model Encoding
Specification
MODEL | RSP-1500-5 | RSP-1500-12 | RSP-1500-15 | RSP-1500-24 | RSP-1500-27 | RSP-1500-48 | |
OUTPUT |
DC VOLTAGE | 5V | 12V | 15V | 24V | 27V | 48V |
RATED CURRENT | 240A | 125A | 100A | 63A | 56A | 32A | |
CURRENT RANGE | 0 ~ 240A | 0 ~ 125A | 0 ~ 100A | 0 ~ 63A | 0 ~ 56A | 0 ~ 32A | |
RATED POWER | 1200W | 1500W | 1500W | 1512W | 1512W | 1536W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 4.5 ~ 5.5V | 10 ~ 13.5V | 13.5 ~ 16.5V | 20 ~ 26.4V | 24 ~ 30V | 43 ~ 56V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1500ms, 100ms at full load | ||||||
HOLD UP TIME (Typ.) | 10ms at full load | 14ms at full load | 16ms at full load | ||||
INPUT |
VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
POWER FACTOR (Typ.) | 0.95/230VAC 0.98/115VAC at full load | ||||||
EFFICIENCY (Typ.) | 80% | 87% | 87% | 90% | 90% | 91% | |
AC CURRENT (Typ.) | 17A/115VAC 8A/230VAC | ||||||
INRUSH CURRENT (Typ.) | 30A/115VAC 60A/230VAC | ||||||
LEAKAGE CURRENT | <2.0mA / 240VAC | ||||||
PROTECTION |
OVERLOAD Note.4 |
105 ~135% rated output power | |||||
Protection type: Constant current limiting unit will shut down o/p voltage after 5sec. Re-power on to recover | |||||||
OVER VOLTAGE |
5.75 ~ 6.75V | 13.8 ~ 16.8V | 17 ~ 20.5V | 27.6 ~ 32.4V | 31 ~ 36.5V | 57.6 ~ 67.2V | |
Protection type: Shut down o/p voltage, re-power on to recover | |||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||||||
FUNCTION |
OUTPUT VOLTAGE PROGRAMMABLE(PV) | Adjustment of output voltage is allowable to 70 ~ 100% of nominal output voltage. Please refer to the Function Manual. | |||||
CURRENT SHARING | Up to 6000W or (3+1) units. Please refer to the Function Manual. | ||||||
AUXILIARY POWER | [email protected] (Only for Remote ON-OFF control) | ||||||
REMOTE ON-OFF CONTROL | Please see the Function Manual. | ||||||
REMOTE SENSE | Compensate voltage drop on the load wiring up to 0.3V. Please refer to the Function Manual. | ||||||
ALARM SIGNAL OUTPUT | Power OK signal. Please see the Function Manual. | ||||||
ENVIRONMENT |
WORKING TEMP. | -20 ~ +70℃ (Refer to “Derating Curve”) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | ||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
SAFETY & EMC (Note 5) |
SAFETY STANDARDS | UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS14336-1, AS/NZS62368.1, EAC TP TC 004 approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION |
Parameter | Standard | Test Level / Note | ||||
Conducted | BS EN/EN55032 (CISPR32) | Class B | |||||
Radiated | BS EN/EN55032 (CISPR32) | Class A | |||||
Harmonic Current | BS EN/EN61000-3-2 | —– | |||||
Voltage Flicker | BS EN/EN61000-3-3 | —– | |||||
EMC IMMUNITY |
BS EN/EN55035, BS EN/EN61000-6-2, BSMI CNS13438 | ||||||
Parameter | Standard | Test Level / Note | |||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | |||||
Radiated | BS EN/EN61000-4-3 | Level 3 | |||||
EFT / Burst | BS EN/EN61000-4-4 | Level 2 | |||||
Surge | BS EN/EN61000-4-5 | Level 3, 2KV/Line-Earth ; Level 2, 1KV/Line-Line | |||||
Conducted | BS EN/EN61000-4-6 | Level 3 | |||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | |||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
|||||
OTHERS |
MTBF | 814.4K hrs min. Telcordia SR-332 (Bellcore); 90.4K hrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 278*127*83.5mm (L*W*H) | ||||||
PACKING | 3.0Kg; 4pcs/13Kg/1.19CUFT |
Application
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Burn-in facility
- Digital broadcasting
- RF application