HRP-600N3 series
June 27, 2023RSP-100 series
June 29, 2023MW Mean Well Meanwell 75W Single Output with PFC Fucntion Switching Power Supply RSP-75 series
Features
Universal AC input / Full range
Built-in active PFC function
High efficiency up to 89%
Cooling by free air convection
Built-in remote ON-OFF control
Protections: Short circuit / Overload / Over voltage / Over temperature
LED indicator for power on
3 years warranty
Mean Well Enclosed Switching Power Supply RSP-75 Series Data Sheet Download
Description
Mean Well single output enclosed power supply with PFC function RSP-75 is a 75W single output enclosed type AC/DC power supply. This series operates for 85~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by free air convection, working for the temperature up to 70℃.
Model Encoding
Specification
MODEL | RSP-75-3.3 | RSP-75-5 | RSP-75-7.5 | RSP-75-12 | RSP-75-13.5 | RSP-75-15 | RSP-75-24 | RSP-75-27 | RSP-75-48 | |
OUTPUT |
DC VOLTAGE | 3.3V | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V |
RATED CURRENT | 15A | 15A | 10A | 6.3A | 5.6A | 5A | 3.2A | 2.8A | 1.6A | |
CURRENT RANGE | 0 ~ 15A | 0 ~ 15A | 0 ~ 10A | 0 ~ 6.3A | 0 ~ 5.6A | 0 ~ 5A | 0 ~ 3.2A | 0 ~ 2.8A | 0 ~ 1.6A | |
RATED POWER | 49.5W | 75W | 75W | 75.6W | 75.6W | 75W | 76.8W | 75.6W | 76.8W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 80mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 3.14 ~ 3.63V | 4.75 ~ 5.5V | 7.13 ~ 8.25V | 11.4 ~ 13.2V | 12.8 ~ 14.9V | 14.3 ~ 16.5V | 22.8 ~ 26.4V | 25.7 ~ 29.7V | 45.6 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 600ms, 30ms at full load | |||||||||
HOLD UP TIME (Typ.) | 16ms at full load | |||||||||
INPUT |
VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
POWER FACTOR (Typ.) | PF>0.93/230VAC PF>0.98/115VAC at full load | |||||||||
EFFICIENCY (Typ.) | 76% | 82% | 84% | 85% | 85% | 86% | 87% | 88% | 89% | |
AC CURRENT (Typ.) | 0.9A/115VAC 0.5A/230VAC | |||||||||
INRUSH CURRENT (Typ.) | COLD START 35A/230VAC | |||||||||
LEAKAGE CURRENT | <2mA / 240VAC | |||||||||
PROTECTION |
OVERLOAD | 105 ~ 135% rated output power | ||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
OVER VOLTAGE | 3.63 ~ 4.46V | 5.5 ~ 6.75V | 8.25 ~ 10.13V | 13.2 ~ 16.2V | 14.85 ~ 18.23V | 16.5 ~ 20.25V | 26.4 ~ 32.4V | 29.7 ~ 36.45V | 52.8 ~ 64.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |||||||||
FUNCTION | REMOTE CONTROL | CN1: < 0~0.8VDC POWER ON, 4~10VDC POWER OFF | ||||||||
ENVIRONMENT |
WORKING TEMP. | -25 ~ +70℃ (Refer to “Derating Curve”) | ||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | |||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||||
OVER VOLTAGE CATEGORY | Ⅲ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters | |||||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, BS EN/EN61558-1, BS EN/EN61558-2-16, AS/NZS 62368.1, EAC TP TC 004, CCC GB4943.1,
BSMI CNS14336-1 approved |
||||||||
WITHSTAND VOLTAGE | I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH | |||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, GB9254 Class B, GB17625.1 | |||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020 | |||||||||
OTHERS |
MTBF | 2171.5K hrs min. Telcordia SR-332 (Bellcore); 296.7K hrs min. MIL-HDBK-217F (25℃) | ||||||||
DIMENSION | 159*97*30mm (L*W*H) | |||||||||
PACKING | 0.44Kg; 30pcs/14.2Kg/0.9CUFT |
Application
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Burn-in facility
- RF application