GST220A series
August 23, 2024GST360A series
August 23, 2024MW Mean Well Meanwell 280W AC-DC High Reliability Industrial Adaptor GST280A Series
Features
- Global certificates
- Universal AC input / Full range
- 3 pole AC inlet IEC320-C14,Class I power unit
- Built-in active PFC function
- No load power consumption< 0.15W
- Energy efficiency Level VI
- Comply with EISA 2007/DoE,NRCan,Korea K-MEPS, AU/NZ MEPS.EU ErP and CoC Version 5
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Fully enclosed plastic case
- -30-+70℃ wide range working temperature
- LED indicator for power on
Description
The GST280A series is a highly reliable 280W desktop-style single-output green adaptor. This Class I power unit (with FG) is equipped with a standard IEC320-C14 AC inlet and supports an input voltage range from 85VAC to 264VAC. The series includes models with output voltages ranging from 12VDC to 48VDC, meeting the diverse needs of various consumer electronic devices.
With an efficiency of up to 94% and ultra-low no-load power consumption below 0.5W, the GST280A series complies with key international energy efficiency standards, including USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea K-MEPS, and EU ErP. These features ensure energy savings in both active and standby modes.
Housed in a 94V-0 flame-retardant plastic enclosure, the GST280A series is certified to meet global safety regulations, making it a dependable and energy-efficient choice for a wide range of applications.
Mean Well Industrial Desktop Adaptor GST280A Series Model Encoding
Mean Well Industrial Desktop Adaptor GST280A Series Data Sheet Download
Specification
ORDER NO. | GST280A12-C6P | GST280A15-C6P | GST280A20-C6P | GST280A24-C6P | GST280A48-C6P | |||
OUTPUT |
SAFETY MODEL NO. | GST280A12 | GST280A15 | GST280A20 | GST280A24 | GST280A48 | ||
DC VOLTAGE Note.2 | 12V | 15V | 20V | 24V | 48V | |||
RATED CURRENT | 21A | 17A | 13A | 11.67A | 5.84A | |||
CURRENT RANGE | 0 ~ 21A | 0 ~ 17A | 0 ~ 13A | 0 ~ 11.67A | 0 ~ 5.84A | |||
RATED POWER (max.) | 252W | 255W | 260W | 280.08W | 280.32W | |||
RIPPLE & NOISE (max.) Note.3 | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |||
VOLTAGE TOLERANCE Note.4 | ±5.0% | ±5.0% | ±4.0% | ±3.0% | ±2.0% | |||
LINE REGULATION Note.5 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
LOAD REGULATION | ±5.0% | ±5.0% | ±4.0% | ±3.0% | ±2.0% | |||
SETUP, RISE TIME Note.6 | 2000ms, 20ms / 230VAC 2000ms, 20ms / 115VAC at full load | |||||||
HOLD UP TIME (Typ.) | 16ms / 230VAC 16ms / 115VAC at full load | |||||||
INPUT |
VOLTAGE RANGE Note.7 | 85 ~ 264VAC 120 ~ 370VDC | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
POWER FACTOR (Typ.) | PF>0.95 / 230VAC PF>0.98 / 115VAC at full load | |||||||
EFFICIENCY (Typ.) | 89.5% | 90% | 92% | 93% | 94% | |||
AC CURRENT (Typ.) | 3A / 115VAC 1.5A / 230VAC | |||||||
INRUSH CURRENT (max.) | Cold start 95A / 115VAC 120A / 230VAC | |||||||
LEAKAGE CURRENT (max.) | 1.5mA / 240VAC | |||||||
PROTECTION |
OVERLOAD |
105 ~ 135% rated output power | ||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE |
105 ~ 135% rated output voltage | |||||||
Protection type: Shut down o/p voltage, re-power on to recover | ||||||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |||||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | ||||||
WORKING HUMIDITY | 20% ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFICIENT | ±0.03% / ℃ (0~40℃) | |||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||||
SAFETY & EMC (Note. 10) |
SAFETY STANDARDS Note. 8 | UL62368-1, CSA C22.2 No.62368-1, TUV BS EN/EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J60950-1,AS/NZS 60950.1,
BIS IS13252, KC K60950-1, EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional) approved |
||||||
WITHSTAND VOLTAGE | I/P-O/P: 3KVAC I/P-F/G: 2KVAC O/P-F/G: SHORT | |||||||
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||
EMC EMISSION |
Parameter | Standard | Test Level / Note | |||||
Conducted emission |
BS EN/EN55032(CISPR32), FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B), CNS13438, GB17625.1 EAC TP TC 020,MSIP KN32 |
Class B |
||||||
Radiated emission |
BS EN/EN55032(CISPR32), FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B), CNS13438, GB17625.1 EAC TP TC 020, MSIP KN32 |
Class B |
||||||
Harmonic current | BS EN/EN61000-3-2, GB9254 | Class A | ||||||
Voltage flicker | BS EN/EN61000-3-3 | ——- | ||||||
EMC IMMUNITY |
Parameter | Standard | Test Level /Note | |||||
ESD | BS EN/EN61000-4-2 | Level 4, 15KV air; Level 4, 8KV contact | ||||||
RF field susceptibility | BS EN/EN61000-4-3 | Level 2, 3V/m | ||||||
EFT bursts | BS EN/EN61000-4-4 | Level 2, 1KV | ||||||
Surge susceptibility | BS EN/EN61000-4-5 | Level 3, 1KV/Line-Line, 2KV/Line-FG | ||||||
Conducted susceptibility | BS EN/EN61000-4-6 | Level 2, 3V | ||||||
Magnetic field immunity | BS EN/EN61000-4-8 | Level 2, 3A/m | ||||||
Voltage dips, interruption | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
||||||
OTHERS |
MTBF | 1625.8K hrs min. Telcordia SR-332 (Bellcore); 181.2K hrs min. MIL-HDBK-217F (25℃) | ||||||
DIMENSION | 220*95*46mm (L*W*H) | |||||||
PACKING | 1.25Kg; 12pcs/16Kg/1.09CUFT | |||||||
CONNECTOR |
PLUG | See page 4; Other type available by customer requested | ||||||
CABLE | See page 4; Other type available by customer requested |
Applications
- Consumer electronic devices
- Telecommunication devices
- Office facilities
- Industrial equipments