LPC-35 series
November 12, 2022LPC-100 series
November 13, 202260W Single Output Switching Power Supply LPC-60 series
Features
- Constant current design
- Universal AC input / Full range
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Over voltage
- Cooling by free air convection
- Fully encapsulated with IP67 level (Note.7)
- Fully isolated plastic case
- Class II power unit, no FG
- Class 2 power unit
- Pass LPS
- Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices)(Note.10)
- 100% full load burn-in test
- Low cost, high reliability
- 2 years warranty
LPC-60 Series Data Sheet Download
Specification
MODEL | LPC-60-1050 | LPC-60-1400 | LPC-60-1750 | |
OUTPUT |
RATED CURRENT | 1050mA | 1400mA | 1750mA |
DC VOLTAGE RANGE | 9 ~ 48V | 9 ~ 42V | 9 ~ 34V | |
RATED POWER | 50.4W | 58.8W | 59.5W | |
RIPPLE & NOISE (max.) Note.2 | 200mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE TOLERANCE Note.3 | ±5.0% | |||
CURRENT ACCURACY | ±5.0% | |||
LINE REGULATION | ±1.0% | |||
LOAD REGULATION | ±2.0% | |||
SETUP, RISE TIME Note.6 | 500ms, 120ms / 230VAC 500ms, 120ms / 115VAC at full load | |||
HOLD UP TIME (Typ.) | 50ms/230VAC 16ms/115VAC at full load | |||
INPUT |
VOLTAGE RANGE Note.4 | 90 ~ 264VAC 127 ~ 370VDC | ||
FREQUENCY RANGE | 47 ~ 63Hz | |||
EFFICIENCY (Typ.) | 87% | 85% | 87% | |
AC CURRENT (Typ.) | 1.2A/115VAC 0.7A/230VAC | |||
INRUSH CURRENT(Typ.) | COLD START 60A (twidth=540μs measured at 50% Ipeak) at 230VAC | |||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | |||
LEAKAGE CURRENT | 0.25mA / 240VAC | |||
PROTECTION | OVER VOLTAGE | 50.4 ~ 60V | 44.1 ~ 56.7V | 39.1 ~ 45.9V |
Protection type: Shut off o/p voltage, clamping by TVS diode | ||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | ||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | |||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||
SAFETY & EMC |
SAFETY STANDARDS | UL1310, CAN/CSA C22.2 No. 223-M91(for LPC-60-1750 only), BIS IS15885(except for LPC-60-1750), EAC TP TC 004, IP67, IEC62368-1, BS EN/EN62368-1 approved | ||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC | |||
ISOLATION RESISTANCE | I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH | |||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class A, BS EN/EN61000-3-3, EAC TP TC 020 | |||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, light industry level, EAC TP TC 020 | |||
OTHERS |
MTBF | 5269.3K hrs min. Telcordia SR-332 (Bellcore); 567.2K hrs min. MIL-HDBK-217F (25℃) | ||
DIMENSION | 162.5*42.5*32mm (L*W*H) | |||
PACKING | 0.4Kg; 32pcs/13.8Kg/0.63CUFT |