LPF-90D series
November 9, 2022LPC-20 series
November 10, 202290W Constant Voltage + Constant Current LED Driver LPF-90 series
Features
- Constant Voltage + Constant Current mode output
- Plastic housing with Class II design
- Built-in active PFC function
- Class 2 power unit
- Fully encapsulated with IP67 level
- Typical lifetime>50000 hours
- 5 years warranty
LPF-90 Series Data Sheet Download
Description
LPF-90 series is a 90W AC/DC LED driver featuring the dual modes constant voltage and constant current output. LPF-90 operates from 90~305VAC and offers models with different rated voltage ranging between 15V and 54V. Thanks to the hign efficiency up to 91%, with the fanless design, the entire series is able to operate for -40℃ ~ +70℃ case temperature under free air convection. The entire series is rated with IP67 ingress protection level and is suitable to work for a variety of applications at dry, damp or wet locations.
Model Encoding
Specification
MODEL | LPF-90-15 | LPF-90-20 | LPF-90-24 | LPF-90-30 | LPF-90-36 | LPF-90-42 | LPF-90-48 | LPF-90-54 | |
OUTPUT |
DC VOLTAGE | 15V | 20V | 24V | 30V | 36V | 42V | 48V | 54V |
CONSTANT CURRENT REGION Note.2 | 9 ~ 15V | 12 ~ 20V | 14.4 ~ 24V | 18 ~ 30V | 21.6 ~ 36V | 25.2 ~ 42V | 28.8 ~ 48V | 32.4 ~ 54V | |
RATED CURRENT | 5A | 4.5A | 3.75A | 3A | 2.5A | 2.15A | 1.88A | 1.67A | |
RATED POWER Note.5 | 75W | 90W | 90W | 90W | 90W | 90.3W | 90.24W | 90.18W | |
RIPPLE & NOISE (max.) Note.3 | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE TOLERANCE Note.4 | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.5% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME Note.6 | 1200ms, 200ms / 115VAC 500ms, 200ms / 230VAC | ||||||||
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC | ||||||||
INPUT |
VOLTAGE RANGE Note.5 | 90 ~ 305VAC 127 ~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” section) |
|||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||
POWER FACTOR | PF≧0.97/115VAC, PF≧0.96/230VAC, PF≧0.92/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section) |
||||||||
TOTAL HARMONIC DISTORTION | THD< 20% (@load≧60%/115VC,230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section) |
||||||||
EFFICIENCY (Typ.) | 89% | 90% | 90.5% | 91% | 91% | 91% | 91% | 91% | |
AC CURRENT | 0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC | ||||||||
INRUSH CURRENT(Typ.) | COLD START 70A (twidth=435μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | ||||||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | ||||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | ||||||||
PROTECTION |
OVER CURRENT | 95 ~ 108% | |||||||
Constant current limiting, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE | 18 ~ 21V | 23 ~ 27V | 28 ~ 34V | 34 ~ 38V | 41 ~ 46V | 47 ~ 53V | 54 ~ 60V | 59 ~ 65V | |
Shut down o/p voltage, re-power on to recover | |||||||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | ||||||||
ENVIRONMENT |
WORKING TEMP. | Tcase=-40 ~ +70℃ (Please refer to “OUTPUT LOAD vs TEMPERATURE” section) | |||||||
MAX. CASE TEMP. | Tcase=+70℃ | ||||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | ||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | ||||||||
SAFETY & EMC |
SAFETY STANDARDS Note.8 | UL8750(type”HL”), CSA C22.2 No.250.13-12, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384, J61347-1, J61347-2-13, EAC TP TC 004, GB19510.1,GB19510.14,IP67 approved ; Design refer to UL60950-1 | |||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC | ||||||||
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||
EMC EMISSION Note.8 | Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load≧60%); BS EN/EN61000-3-3, GB17743 and GB17625.1, EAC TP TC 020 | ||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Line 2KV), EAC TP TC 020 | ||||||||
OTHERS |
MTBF | 3292.9K hrs min. Telcordia SR-332 (Bellcore); 301.7Khrs min. MIL-HDBK-217F (25℃) | |||||||
DIMENSION | 161*61*36mm (L*W*H) | ||||||||
PACKING | 0.7Kg; 20pcs/15Kg/0.73CUFT |
Application
- LED panel lighting
- LED downlight
- LED decorative lighting
- LED tunnel lighting
- Moving sign
- Type “HL” for use in Class I, Division 2 hazardous (Classified) location.