RSD-150 series
March 20, 2023RSD-300 series
March 20, 2023MW Mean Well Meanwell 200W Reliable Railway DC-DC Converter RSD-200 Series
Features
- Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
- 2:1 wide input range
- Protections: Short circuit / Overload / Over voltage / Input reverse polarity
- 4000VDC I/O isolation (reinforced isolation)
- Cooling by free air convection
- Half encapsulated
- Built-in constant current limiting circuit
- 1U low profile 36mm
- All using 105℃ long life electrolytic capacitors
- LED indicator for power on
- 100% full load burn-in test
- 3 years warranty
Mean Well DC-DC Converter RSD-200 Series Data Sheet Download
Specification
MODEL | RSD-200B-12 | RSD-200B-24 | RSD-200B-48 | RSD-200C-12 | RSD-200C-24 | RSD-200C-48 | RSD-200D-12 | RSD-200D-24 | RSD-200D-48 | ||
OUTPUT |
DC VOLTAGE | 12V | 24V | 48V | 12V | 24V | 48V | 12V | 24V | 48V | |
RATED CURRENT | 16.7A | 8.4A | 4.2A | 16.7A | 8.4A | 4.2A | 16.7A | 8.4A | 4.2A | ||
CURRENT RANGE | 0 ~ 16.7A | 0 ~ 8.4A | 0 ~ 4.2A | 0 ~ 16.7A | 0 ~ 8.4A | 0 ~ 4.2A | 0 ~ 16.7A | 0 ~ 8.4A | 0 ~ 4.2A | ||
RATED POWER | 200.4W | 201.6W | 201.6W | 200.4W | 201.6W | 201.6W | 200.4W | 201.6W | 201.6W | ||
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | 150mVp-p | 180mVp-p | 120mVp-p | 150mVp-p | 180mVp-p | 120mVp-p | 150mVp-p | 180mVp-p | ||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ||
LINE REGULATION | ±0.2% | ±0.2% | ±0.5% | ±0.2% | ±0.2% | ±0.5% | ±0.2% | ±0.2% | ±0.5% | ||
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||
SETUP, RISE TIME | 800ms, 50ms at full load | ||||||||||
HOLD UP TIME (Typ.) | Please refer to page 3 Hold up Time (Load de-rating curve) | ||||||||||
INPUT |
VOLTAGE RANGE | CONTINUOUS | 16.8 ~ 31.2VDC | 33.6 ~ 62.4VDC | 67.2 ~ 143VDC | ||||||
1 SEC. | 14.4 ~ 33.6VDC | 28.8 ~ 67.2VDC | 57.6 ~ 154VDC | ||||||||
EFFICIENCY (Typ.) | 89% | 89% | 89% | 91% | 91% | 91% | 91% | 91% | 91% | ||
DC CURRENT (Typ.) | 9.6A/24V | 9.6A/24V | 9.6A/24V | 4.8A/48V | 4.8A/48V | 4.8A/48V | 2.1A/110V | 2.1A/110V | 2.1A/110V | ||
INRUSH CURRENT (Typ.) | 45A/24VDC | 45A/48VDC | 45A/110VDC | ||||||||
INTERRUPTION OF VOLTAGE SUPPLY |
EN50155:2007-B/C- type comply with S1 level @ full load, comply with S2 level @ 70% load; D-type comply with S2 level @ full load | ||||||||||
EN50155:2017-Comply with S1 level | |||||||||||
PROTECTION |
OVERLOAD |
105 ~ 135% rated output power | |||||||||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | |||||||||||
OVER VOLTAGE |
13.8 ~ 16.2V | 27.6 ~ 32.4V | 55.2 ~ 64.8V | 13.8 ~ 16.2V | 27.6 ~ 32.4V | 55.2 ~ 64.8V | 13.8 ~ 16.2V | 27.6 ~ 32.4V | 55.2 ~ 64.8V | ||
Protection type: Shut down o/p voltage, re-power on to recover | |||||||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||||||||||
ENVIRONMENT |
WORKING TEMP. | -40 ~ +55℃ (no derating); +70℃ @ 60% load by free air convection; +70℃ no derating with external base plate, TX class compliance | |||||||||
WORKING HUMIDITY | 5 ~ 95% RH non-condensing | ||||||||||
STORAGE TEMP. | -40 ~ +85℃ | ||||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: compliance to IEC61373 | ||||||||||
OPERATING ALTITUDE | 5000 meters | ||||||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS | UL 62368-1, IEC 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refers to BS EN/EN62368-1 | |||||||||
WITHSTAND VOLTAGE | I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC | ||||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B, EAC TP TC 020 | ||||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8, BS EN/EN55035, light industry level, EAC TP TC 020 | ||||||||||
RAILWAY STANDARD | BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC; BS EN/EN45545-2 for fire protection | ||||||||||
OTHERS |
MTBF | 2125.5K hrs min. Telcordia SR-332 (Bellcore); 218.2K hrs min. MIL-HDBK-217F (25℃) | |||||||||
DIMENSION | 191*86*40mm (L*W*H) | ||||||||||
PACKING | 0.94Kg; 12pcs/12.3Kg/0.73CUFT |
Applications
- Bus, tram, metro or railway system
- Highly vibrating, highly dusty, extremely low or high temperature harsh environment
- Wireless network
- Telecom or datacom system
- Industry control system