RSD-200 series
March 20, 2023RSD-500 series
March 20, 2023MW Mean Well Meanwell 300W Reliable Railway DC-DC Converter RSD-300 Series
Features
- Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
- 2:1 wide input range
- Protections: Short circuit / Overload / Over voltage / Input reverse polarity
- 4000VDC I/O isolation (reinforced isolation)
- Cooling by free air convection
- Half encapsulated
- Built-in constant current limiting circuit
- 1U low profile 36mm
- All using 105℃ long life electrolytic capacitors
- LED indicator for power on
- 100% full load burn-in test
- 3 years warranty
Mean Well DC-DC Converter RSD-300 Series Data Sheet Download
Specification
MODEL | RSD-300B-5 | RSD-300B-12 | RSD-300B-24 | RSD-300B-48 | RSD-300C-5 | RSD-300C-12 | RSD-300C-24 | RSD-300C-48 | ||
OUTPUT |
DC VOLTAGE | 5V | 12V | 24V | 48V | 5V | 12V | 24V | 48V | |
RATED CURRENT | 42A | 22.5A | 11.3A | 5.7A | 42A | 25A | 12.5A | 6.3A | ||
CURRENT RANGE | 0 ~ 42A | 0 ~ 22.5A | 0 ~ 11.3A | 0 ~ 5.7A | 0 ~ 42A | 0 ~ 25A | 0 ~ 12.5A | 0 ~ 6.3A | ||
RATED POWER | 210W | 270W | 271.2W | 273.6W | 210W | 300W | 300W | 302.4W | ||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | 150mVp-p | 180mVp-p | 100mVp-p | 120mVp-p | 150mVp-p | 180mVp-p | ||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ||
LINE REGULATION | ±0.5% | ±0.3% | ±0.2% | ±0.5% | ±0.5% | ±0.3% | ±0.2% | ±0.5% | ||
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||
SETUP, RISE TIME | 800ms, 50ms at full load | |||||||||
HOLD UP TIME (Typ.) | Please refer to page 5,6 Hold up Time (Load de-rating curve) | |||||||||
INPUT |
VOLTAGE RANGE | CONTINUOUS | 16.8 ~ 31.2VDC | 33.6 ~ 62.4VDC | ||||||
1 SEC. | 14.4 ~ 33.6VDC | 28.8 ~ 67.2VDC | ||||||||
EFFICIENCY (Typ.) | 89% | 89.5% | 90% | 91.5% | 90.5% | 91% | 91.5% | 92% | ||
DC CURRENT (Typ.) | 9.7A/24V | 14.6A/24V | 14.6A/24V | 14.6A/24V | 4.8A/48V | 7.2A/48V | 7.2A/48V | 7.2A/48V | ||
INRUSH CURRENT (Typ.) | 45A/24VDC | 45A/48VDC | ||||||||
INTERRUPTION OF VOLTAGE SUPPLY |
EN50155:2007-B/C- type comply with S1 level @ full load, comply with S2 level @ 70% load | |||||||||
EN50155:2017-Comply with S1 level | ||||||||||
PROTECTION |
OVERLOAD |
105 ~ 135% rated output power | ||||||||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
OVER VOLTAGE |
5.75 ~ 7V | 13.8 ~ 16.2V | 27.6 ~ 32.4V | 55.2 ~ 64.8V | 5.75 ~ 7V | 13.8 ~ 16.2V | 27.6 ~ 32.4V | 55.2 ~ 64.8V | ||
Protection type: Shut down o/p voltage, re-power on to recover | ||||||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |||||||||
ENVIRONMENT |
WORKING TEMP. | -40 ~ +55℃ (no derating); +70℃ @ 60% load by free air convection; +70℃ no derating with external base plate, TX class compliance | ||||||||
WORKING HUMIDITY | 5 ~ 95% RH non-condensing | |||||||||
STORAGE TEMP. | -40 ~ +85℃ | |||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 55℃) | |||||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: compliance to IEC61373 | |||||||||
OPERATING ALTITUDE | 5000 meters | |||||||||
SAFETY & EMC (Note 5) |
SAFETY STANDARDS | IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refers to BS EN/EN62368-1 | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B, EAC TP TC 020 | |||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8, BS EN/EN55035, light industry level, EAC TP TC 020 | |||||||||
RAILWAY STANDARD | BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration,BS EN/EN50121-3-2 for EMC;BS EN/EN45545-2 for fire protection | |||||||||
OTHERS |
MTBF | 1850.1K hrs min. Telcordia SR-332 (Bellcore); 130.8K hrs min. MIL-HDBK-217F (25℃) | ||||||||
DIMENSION | 216*96.5*40mm (L*W*H) | |||||||||
PACKING | 1.19Kg; 12pcs/15.3Kg/0.97CUFT |
MODEL | RSD-300D-5 | RSD-300D-12 | RSD-300D-24 | RSD-300D-48 | RSD-300E-5 | RSD-300E-12 | RSD-300E-24 | RSD-300E-48 | ||
OUTPUT |
DC VOLTAGE | 5V | 12V | 24V | 48V | 5V | 12V | 24V | 48V | |
RATED CURRENT | 42A | 25A | 12.5A | 6.3A | 42A | 25A | 12.5A | 6.3A | ||
CURRENT RANGE | 0 ~ 42A | 0 ~ 25A | 0 ~ 12.5A | 0 ~ 6.3A | 0 ~ 42A | 0 ~ 25A | 0 ~ 12.5A | 0 ~ 6.3A | ||
RATED POWER | 210W | 300W | 300W | 302.4W | 210W | 300W | 300W | 302.4W | ||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | 150mVp-p | 180mVp-p | 100mVp-p | 120mVp-p | 150mVp-p | 180mVp-p | ||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ||
LINE REGULATION | ±0.5% | ±0.2% | ±0.2% | ±0.5% | ±0.5% | ±0.3% | ±0.2% | ±0.5% | ||
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||
SETUP, RISE TIME | 800ms, 50ms at full load | |||||||||
HOLD UP TIME (Typ.) | Please refer to page 5,6 Hold up Time (Load de-rating curve) | |||||||||
INPUT |
VOLTAGE RANGE | CONTINUOUS | 67.2 ~ 143VDC | 25.2 ~ 46.8VDC | ||||||
1 SEC. | 57.6 ~ 154VDC | 21.6 ~ 50.4VDC | ||||||||
EFFICIENCY (Typ.) | 90% | 91.5% | 91.5% | 91.5% | 88% | 90% | 91% | 91% | ||
DC CURRENT (Typ.) | 2.1A/110V | 3.1A/110V | 3.1A/110V | 3.1A/110V | 6.5A/36V | 9.2A/36V | 9.2A/36V | 9.2A/36V | ||
INRUSH CURRENT (Typ.) | 45A/110VDC | 45A/36VDC | ||||||||
INTERRUPTION OF VOLTAGE SUPPLY |
EN50155:2007-D-type and E-5 comply with S2 level @ full load; other E- type comply with S1 level @ full load, comply with S2 level @ 70% load | |||||||||
EN50155:2017-Comply with S1 level | ||||||||||
PROTECTION |
OVERLOAD |
105 ~ 135% rated output power | ||||||||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
OVER VOLTAGE |
5.75 ~ 7V | 13.8 ~ 16.2V | 27.6 ~ 32.4V | 55.2 ~ 64.8V | 5.75 ~ 7V | 13.8 ~ 16.2V | 27.6 ~ 32.4V | 55.2 ~ 64.8V | ||
Protection type: Shut down o/p voltage, re-power on to recover | ||||||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |||||||||
ENVIRONMENT |
WORKING TEMP. | -40 ~ +55℃ (no derating); +70℃ @ 60% load by free air convection; +70℃ no derating with external base plate, TX class compliance | ||||||||
WORKING HUMIDITY | 5 ~ 95% RH non-condensing | |||||||||
STORAGE TEMP. | -40 ~ +85℃ | |||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 55℃) | |||||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: compliance to IEC61373 | |||||||||
OPERATING ALTITUDE | 5000 meters | |||||||||
SAFETY & EMC (Note 5) |
SAFETY STANDARDS | IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refers to BS EN/EN62368-1 | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B, EAC TP TC 020 | |||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8, BS EN/EN55035, light industry level, EAC TP TC 020 | |||||||||
RAILWAY STANDARD | BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC; BS EN/EN45545-2 for fire protection | |||||||||
OTHERS |
MTBF | 1850.1K hrs min. Telcordia SR-332 (Bellcore); 130.8K hrs min. MIL-HDBK-217F (25℃) | ||||||||
DIMENSION | 216*96.5*40mm (L*W*H) | |||||||||
PACKING | 1.19Kg; 12pcs/15.3Kg/0.97CUFT |
MODEL | RSD-300F-5 | RSD-300F-12 | RSD-300F-24 | RSD-300F-48 | ||
OUTPUT |
DC VOLTAGE | 5V | 12V | 24V | 48V | |
RATED CURRENT | 42A | 25A | 12.5A | 6.3A | ||
CURRENT RANGE | 0 ~ 42A | 0 ~ 25A | 0 ~ 12.5A | 0 ~ 6.3A | ||
RATED POWER | 210W | 300W | 300W | 302.4W | ||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | 150mVp-p | 180mVp-p | ||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ||
LINE REGULATION | ±0.5% | ±0.3% | ±0.2% | ±0.5% | ||
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||
SETUP, RISE TIME | 800ms, 50ms at full load | |||||
HOLD UP TIME (Typ.) | Please refer to page 5,6 Hold up Time (Load de-rating curve) | |||||
INPUT |
VOLTAGE RANGE | CONTINUOUS | 50.4 ~ 93.6VDC | |||
1 SEC. | 43.2 ~ 100.8VDC | |||||
EFFICIENCY (Typ.) | 89% | 91% | 91% | 91.5% | ||
DC CURRENT (Typ.) | 3.25A/72V | 4.6A/72V | 4.6A/72V | 4.6A/72V | ||
INRUSH CURRENT (Typ.) | 45A/72VDC | |||||
INTERRUPTION OF VOLTAGE SUPPLY |
EN50155:2007-F-type comply with S2 level @ full load | |||||
EN50155:2017-Comply with S1 level | ||||||
PROTECTION |
OVERLOAD |
105 ~ 135% rated output power | ||||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||||||
OVER VOLTAGE |
5.75 ~ 7V | 13.8 ~ 16.2V | 27.6 ~ 32.4V | 55.2 ~ 64.8V | ||
Protection type: Shut down o/p voltage, re-power on to recover | ||||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |||||
ENVIRONMENT |
WORKING TEMP. | -40 ~ +55℃ (no derating); +70℃ @ 60% load by free air convection; +70℃ no derating with external base plate, TX class compliance | ||||
WORKING HUMIDITY | 5 ~ 95% RH non-condensing | |||||
STORAGE TEMP. | -40 ~ +85℃ | |||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 55℃) | |||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: compliance to IEC61373 | |||||
OPERATING ALTITUDE | 5000 meters | |||||
SAFETY & EMC (Note 5) |
SAFETY STANDARDS | IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refers to BS EN/EN62368-1 | ||||
WITHSTAND VOLTAGE | I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC | |||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B, EAC TP TC 020 | |||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8, BS EN/EN55035, light industry level, EAC TP TC 020 | |||||
RAILWAY STANDARD | BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC; BS EN/EN45545-2 for fire protection | |||||
OTHERS |
MTBF | 1850.1K hrs min. Telcordia SR-332 (Bellcore); 130.8K hrs min. MIL-HDBK-217F (25℃) | ||||
DIMENSION | 216*96.5*40mm (L*W*H) | |||||
PACKING | 1.19Kg; 12pcs/15.3Kg/0.97CUFT |
Applications
- Bus, tram, metro or railway system
- Highly vibrating, highly dusty, extremely low or high temperature harsh environment
- Wireless network
- Telecom or datacom system
- Industry control system