Features
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- 1.8″x2.5″ compact size
- No load power consumption<0.3W
- Operating altitude up to 3000 meters
- 3 years warranty
Mean Well Power Supply EPS-15 Series Data Sheet Download
Specification
MODEL | EPS-15-3.3 | EPS-15-5 | EPS-15-7.5 | EPS-15-12 | EPS-15-15 | EPS-15-24 | EPS-15-27 | EPS-15-36 | EPS-15-48 | |
OUTPUT |
DC VOLTAGE | 3.3V | 5V | 7.5V | 12V | 15V | 24V | 27V | 36V | 48V |
RATED CURRENT | 3A | 3A | 2A | 1.25A | 1A | 0.625A | 0.56A | 0.42A | 0.313A | |
CURRENT RANGE | 0 ~ 3.3A | 0 ~ 3.3A | 0 ~ 2.2A | 0 ~ 1.38A | 0 ~ 1.1A | 0 ~ 0.69A | 0 ~ 0.615A | 0 ~ 0.46A | 0 ~ 0.344A | |
RATED POWER | 9.9W | 15W | 15W | 15W | 15W | 15W | 15.12W | 15.12W | 15.02W | |
PEAK LOAD(10sec.) Note.6 | 10.89W | 16.5W | 16.5W | 16.56W | 16.5W | 16.56W | 16.6W | 16.56W | 16.51W | |
RIPPLE & NOISE (max.) Note.2 | 50mVp-p | 50mVp-p | 80mVp-p | 80mVp-p | 100mVp-p | 150mVp-p | 180mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 3.1 ~ 3.6V | 4.75 ~ 5.5V | 7.13 ~ 8.25V | 10.8 ~ 13.5V | 13.5 ~ 16.5V | 21.6 ~ 27V | 24.3 ~ 29.7V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load | |||||||||
HOLD UP TIME (Typ.) | 50ms/230VAC 16ms/115VAC at full load | |||||||||
INPUT |
VOLTAGE RANGE Note.5 | 85 ~ 264VAC 120 ~ 370VDC [DC input operation possible by connecting AC/N(+), AC/L(-)] | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
EFFICIENCY (Typ.) | 75% | 78% | 81% | 82% | 83% | 83% | 84% | 85% | 85% | |
AC CURRENT (Typ.) | 0.4A/115VAC 0.2A/230VAC | |||||||||
INRUSH CURRENT (Typ.) | COLD START 45A/230VAC | |||||||||
LEAKAGE CURRENT | <1mA/240VAC | |||||||||
PROTECTION |
OVER LOAD |
115 ~ 150% rated output power | ||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||
OVER VOLTAGE |
3.8 ~ 4.85V | 5.6 ~ 6.75V | 8.63~ 10.1V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 33V | 31.05 ~ 36.45V | 39.7 ~ 46.8V | 55.2 ~ 65.8V | |
Protection type: Shut down o/p voltage, Clamping by zener diode | ||||||||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | ||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||||
OPERATING ALTITUDE Note.7 | 3000 meters | |||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, CCC GB4943.1 approved | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2, -3, EAC TP TC 020, GB9254 Class B, GB17625.1 | |||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, heavy industry level, EAC TP TC 020 | |||||||||
OTHERS |
MTBF | 6024.7K hrs min. Telcordia SR-332 (Bellcore); 849.3K hrs min. MIL-HDBK-217F (25℃) | ||||||||
DIMENSION | 63.5*45.7*24mm (L*W*H) | |||||||||
PACKING | 0.057Kg; 120pcs/ 7.84Kg/0.94CUFT |