EPS-15 series
March 5, 2023EPS-35 series
March 5, 2023MW Mean Well Meanwell 25W Single Output Power Supply EPS-25 Series
Features
- Universal AC input / Full range
- High efficiency up to 90%
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- 3″×2″ compact size
- LED indicator for power on
- No load power consumption<0.3W
- 3 years warranty
Mean Well Power Supply EPS-25 Series Data Sheet Download
Specification
MODEL | EPS-25-3.3 | EPS-25-5 | EPS-25-7.5 | EPS-25-12 | EPS-25-15 | EPS-25-24 | EPS-25-27 | EPS-25-36 | EPS-25-48 | |
OUTPUT |
DC VOLTAGE | 3.3V | 5V | 7.5V | 12V | 15V | 24V | 27V | 36V | 48V |
RATED CURRENT | 5A | 5A | 3.4A | 2.1A | 1.7A | 1.05A | 0.95A | 0.7A | 0.53A | |
CURRENT RANGE | 0 ~ 5.5A | 0 ~ 5.5A | 0 ~ 3.74A | 0 ~ 2.34A | 0 ~ 1.87A | 0 ~ 1.17A | 0 ~ 1.05A | 0 ~ 0.78A | 0 ~ 0.59A | |
RATED POWER | 16.5W | 25W | 25.5W | 25.2W | 25.5W | 25.2W | 25.65W | 25.2W | 25.44W | |
PEAK LOAD (10sec.) Note.6 | 18.15W | 27.5W | 28.05W | 28.08W | 28.05W | 28.08W | 28.35W | 28.08W | 28.32W | |
RIPPLE & NOISE (max.) Note.2 | 60mVp-p | 60mVp-p | 80mVp-p | 100mVp-p | 100mVp-p | 180mVp-p | 180mVp-p | 200mVp-p | 240mVp-p | |
VOLTAGE ADJ. RANGE | 3.1 ~ 3.6V | 4.75 ~ 5.5V | 7.13 ~ 8.25V | 10.8 ~ 13.5V | 13.5 ~ 16.5V | 21.6 ~ 27V | 24.3 ~ 29.7V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1000ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load | |||||||||
HOLD UP TIME (Typ.) | 50ms/230VAC 16ms/115VAC at full load | |||||||||
INPUT |
VOLTAGE RANGE Note.5 | 85 ~ 264VAC 120 ~ 370VDC | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
EFFICIENCY (Typ.) | 79% | 81% | 83% | 86% | 87% | 88% | 89% | 89% | 90% | |
AC CURRENT (Typ.) | 0.6A/115VAC 0.4A/230VAC | |||||||||
INRUSH CURRENT (Typ.) | COLD START 35A/230VAC | |||||||||
LEAKAGE CURRENT | <1mA/240VAC | |||||||||
PROTECTION |
OVER LOAD |
115 ~ 170% rated output power | ||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||
OVER VOLTAGE |
3.7 ~ 4.6V | 5.6 ~ 6.75V | 8.63~ 10.5V | 14 ~ 17V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | 31.05 ~ 36.45V | 39.7 ~ 46.8V | 53.3 ~ 64.8V | |
Protection type: Shut down o/p voltage, re-power on to recover | ||||||||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | ||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||||
OPERATING ALTITUDE Note.8 | 2000 meters | |||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2, -3, EAC TP TC 020 | |||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, heavy industry level, EAC TP TC 020 | |||||||||
OTHERS |
MTBF | 3830.1K hrs min. Telcordia SR-332 (Bellcore); 655.4K hrs min. MIL-HDBK-217F (25℃) | ||||||||
DIMENSION | 76.2*50.8*24mm (L*W*H) | |||||||||
PACKING | 0.081Kg; 120pcs/10.7Kg/0.94CUFT |