Features
- Universal AC input / Full range (up to 305VAC)
- Built-in active PFC function
- No load power consumption <0.5W at remote OFF
- High efficiency up to 96%
- Fanless design, cooling by free air convection
- -40 〜+70℃ wide operating range
- Aluminum case and filling with heat-conducted glue
- Withstand 10G vibration test
- Output voltage and output current can be adjusted through internal potentiometer
- Protections: Short circuit / Over current / Over voltage / Over temperature
- LED indicator for power on
- Operating altitude up to 5000 meters
- 6 years warranty
Mean Well HEP-600 Series Data Sheet Download
Description
HEP-600 is a 600W industrial AC/DC power supply featuring the outstanding capability to operate under highly humid, dusty, oily, and high-vibration harsh environment. The entire series is housed with the aluminum case and fully potted with heat-conducted silicone. Thanks to state-of-the-art design, the working efficiency is up to 96%, enabling HEP-600 perfectly work between -40℃ and +70℃ under free air convection.
In Mean Well power supply HEP Family, there are HEP-100 series, HEP-150 series, HEP-185 series, HEP-240 series, HEP-320 series, HEP-480 series, HEP-600C series, HEP-600 series, HEP-1000 series, HEP-2300-HV series and HEP-2300 series.
Mean Well HEP-600 Series Model Encoding
Specification
MODEL | HEP-600-12 | HEP-600-15 | HEP-600-20 | HEP-600-24 | HEP-600-30 | HEP-600-36 | HEP-600-42 | HEP-600-48 | HEP-600-54 | |
OUTPUT | DC VOLTAGE | 12V | 15V | 20V | 24V | 30V | 36V | 42V | 48V | 54V |
RATED CURRENT | 40A | 36A | 28A | 25A | 20A | 16.7A | 14.3A | 12.5A | 11.2A | |
RATED POWER | 480W | 540W | 560W | 600W | 600W | 601.2W | 600.6W | 600W | 604.8W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 250mVp-p | 250mVp-p | 250mVp-p | 350mVp-p | |
VOLTAGE ADJ. RANGE | 10.2 ~ 12.6V | 12.7 ~ 15.8V | 17 ~ 21V | 20.4 ~ 25.2V | 25.5 ~ 31.5V | 30.6 ~ 37.8V | 35.7 ~ 44.1V | 40.8 ~ 50.4V | 45.9 ~ 56.7V | |
CURRENT ADJ. RANGE | Can be adjusted by internal potentiometer | |||||||||
20 ~ 40A | 18 ~ 36A | 14 ~ 28A | 12.5 ~ 25A | 10 ~ 20A | 8.3 ~ 16.7A | 7.1 ~ 14.3A | 6.2 ~ 12.5A | 5.6 ~ 11.2A | ||
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±2.0% | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.0% | ±1.5% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME Note.5 | 500ms, 80ms at full load 230VAC /115VAC | |||||||||
HOLD UP TIME (Typ.) | 15ms at full load 230VAC /115VAC | |||||||||
INPUT | VOLTAGE RANGE Note.4 | 85~264VAC(277VAC operational) 120~370VDC(390VDC operational) | ||||||||
FREQUENCY RANGE | 47 ~63Hz | |||||||||
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load | |||||||||
EFFICIENCY (Typ.) | 93% 94% 95% | 95% 95.5% 95.5% 96% 96% 96% | ||||||||
AC CURRENT (Typ.) | 7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC | |||||||||
INRUSH CURRENT(Typ.) | COLD START 70A(twidth=1000ps measured at 50% Ipeak) at 230VAC | |||||||||
LEAKAGE CURRENT | <0.75mA / 277VAC | |||||||||
PROTECTION | OVER CURRENT | 105~125% | ||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
SHORT CIRCUIT | Constant current limiting, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE | 13 ~ 16V 16.5 ~ 20.5V 22 ~ 26V | 26 ~ 30V | 32.5 ~ 36.5V| 39.5 ~ 43.5V| 46 ~ 50V | 52.5 ~ 56.5V| 59 ~ 63V | ||||||||
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |||||||||
FUNCTION | REMOTE ON/OFF CONTROL | Power on : “Hi” >2 ~ 5V or Open circuit Power off : “Low” <0 ~ 0.5V or Short circuit | ||||||||
5V STANDBY | 5Vsb : [email protected] ; tolerance ±5%, ripple : 100mVp-p(max.) | |||||||||
ENVIRONMENT | WORKING TEMP. | -40 ~ +70 ℃ (Refer to “Derating Curve”) | ||||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 60℃) | |||||||||
VIBRATION | 20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||||
SAFETY & EMC (Note.6) | SAFETY STANDARDS | UL62368-1 ,TUV BS EN/EN62368-1, EAC TP TC 004 approved | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 | |||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, heavy industry level, EAC TP TC 020 | |||||||||
OTHERS | MTBF | 914.7K hrs min. Telcordia SR-332 (Bellcore) ; 76.9K hrs min. MIL-HDBK-217F (25℃) | ||||||||
DIMENSION | 280*144*48.5mm (L*W*H) | |||||||||
PACKING | 3.9Kg; 4pcs/16Kg/0.9CUFT |
Application
- Outdoor telecommunication equipment
- Outdoor electronic signage and billboard
- Petroleum plant or mine shaft facility