March 5, 2023EPP-200 series
March 6, 2023MW Mean Well Meanwell 150W Single Output with PFC Function Power Supply EPP-150 Series
Features
- 4″×2″ compact size
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 93%
- Protections: Short circuit / Overload / Over voltage / Over temperature
- 100W free air convection, 150W with 20CFM forced air
- LED indicator for power on
- No load power consumption<0.5W
- Built-in 12V/0.3A auxiliary output
- 3 years warranty
Mean Well Power Supply EPP-150 Series Data Sheet Download
Specification
MODEL | EPP-150-12 | EPP-150-15 | EPP-150-24 | EPP-150-27 | EPP-150-48 | |
OUTPUT |
DC VOLTAGE | 12V | 15V | 24V | 27V | 48V |
RATED CURRENT (convection) | 8.4A | 6.7A | 4.2A | 3.71A | 2.1A | |
RATED CURRENT (20CFM FAN) | 12.5A | 10A | 6.25A | 5.56A | 3.125A | |
CURRENT RANGE (convection) | 0 ~ 8.4A | 0 ~ 6.7A | 0 ~ 4.2A | 0 ~ 3.71A | 0 ~ 2.1A | |
CURRENT RANGE (20CFM FAN) | 0 ~ 12.5A | 0 ~ 10A | 0 ~ 6.25A | 0 ~ 5.56A | 0 ~ 3.125A | |
RATED POWER (convection) | 100.8W | 100.5W | 100.8W | 100.17W | 100.8W | |
RATED POWER (20CFM FAN) | 150W | 150W | 150W | 150.12W | 150W | |
RIPPLE & NOISE (max.) Note.2 | 130mVp-p | 150mVp-p | 240mVp-p | 240mVp-p | 300mVp-p | |
VOLTAGE ADJ. RANGE | 11.76 ~ 12.6V | 14.7 ~ 15.75V | 23.52 ~ 25.2V | 26.46 ~ 28.35V | 47.04 ~ 50.4V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
SETUP, RISE TIME | 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load | |||||
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC at full load | |||||
INPUT |
VOLTAGE RANGE Note.4 | 90 ~ 264VAC 127 ~ 370VDC | ||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||
POWER FACTOR (Typ.) | PF>0.95/230VAC PF>0.98/115VAC at full load | |||||
EFFICIENCY (Typ.) | 91.5% | 92% | 93% | 92% | 92% | |
AC CURRENT (Typ.) | 1.8A/115VAC 1 A/230VAC | |||||
INRUSH CURRENT (Typ.) | COLD START 70A/230VAC | |||||
LEAKAGE CURRENT | <2mA/240VAC | |||||
PROTECTION |
OVER LOAD | 105 ~ 145% rated output power | ||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||
OVER VOLTAGE | 13.2 ~ 15.6V | 16.83 ~ 19.5V | 27.7 ~ 31.5V | 30.2 ~ 34.05V | 51.3 ~ 62.7V | |
Protection type: Shut down o/p voltage, re-power on to recover | ||||||
OVER TEMPERATURE | Protection type: Shut down o/p voltage, re-power on to recover | |||||
FUNCTION | AUXILIARY POWER(AUX) | |||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | ||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | |||||
TEMP. COEFFICIENT | ||||||
OPERATING ALTITUDE Note.5 | 2000 meters | |||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||
SAFETY & EMC (Note 6) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved | ||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 500VDC / 25℃/ 70% RH | |||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2, -3, EAC TP TC 020 | |||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, heavy industry level, EAC TP TC 020 | |||||
OTHERS |
MTBF | 2002.2K hrs min. Telcordia SR-332 (Bellcore); 207.1K hrs min. MIL-HDBK-217F (25℃) | ||||
DIMENSION | 101.6*50.8*29mm (L*W*H) | |||||
PACKING | 0.2Kg; 72pcs/15.4Kg/0.82CUFT |