XLG-25 series
April 12, 2022MW Mean Well Meanwell 21W Constant Current Mode LED Driver XLG-20 series
Features
‧Constant Current mode output
‧Wide input range 90~305VAC (Class Ⅰ)
‧Built-in active PFC function
‧Class 2 power unit
‧No load power consumption <0.5W
‧IP67 rating for indoor or outdoor installations
‧3 in 1 dimming function (Isolation design)
‧Life time>50,000 hours and 5 years warranty
Mean Well LED Driver XLG-20 Series Data Sheet Download
Description
XLG-20 series is an AC/DC LED driver featuring the constant current mode output. XLG-20 operates from 90~305VAC. Thanks to the high efficiency up to 89%, The entire series is able to operate between -40℃ ~+80℃ wide case temperature range with air convection. The design of metal housing and IP67 ingress protection level allows this series to fit both indoor and outdoor applications. XLG-20 is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.XLG-20 series comply with the latest version of IEC61347/GB7000.1-2015 and UL8750 international safety regulations. The output and dimming circuit are also completely in accordance with the new regulations with isolation to ensure the safety of both user and luminaire system during installation.
In XLG family, there are XLG-20 series, XLG-25 series, XLG-50 series, XLG-75 series, XLG-100 series, XLG-150 series, XLG-200 series, XLG-240 series and XLG-320 series.
Mean Well LED Driver XLG-20 Series Model Encoding
Type | IP Level | Function | Note |
Blank | IP67 | Io fixed. | In Stock |
B | IP67 | Io fixed with 3 in 1 dimming function (1~10Vdc, 10V PWM signal and resistance) | In Stock |
Specification
MODEL | XLG-20-L- | XLG-20-M- | XLG-20-H- | ||
OUTPUT |
RATED CURRENT | 350mA | 500mA | 700mA | |
CONSTANT CURRENT REGION | 32.4 ~ 54V | 25.2 ~ 42V | 18 ~ 30V | ||
RATED POWER | 18.9W | 21W | 21W | ||
OPEN CIRCUIT VOLTAGE (max.) | 60V | 50V | 40V | ||
CURRENT TOLERANCE | ±8.0% | ||||
OUTPUT CURRENT RIPPLE Note.13 | < 20% | ||||
SETUP, RISE TIME | Note.2 | 500ms, 150ms/115VAC, 230VAC | |||
LINE REGULATION | < ±3% | ||||
INPUT |
VOLTAGE RANGE | Note.3 | 90 ~ 305VAC
(Please refer to “STATIC CHARACTERISTIC” section) |
||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
POWER FACTOR | PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.91/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section) |
||||
TOTAL HARMONIC DISTORTION | THD< 20% (@load≧50%/115VC,230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section) |
||||
EFFICIENCY (Typ.) | 89% | 88.5% | 88% | ||
AC CURRENT | 0.3A / 115VAC 0.2A / 230VAC 0.2A/277VAC | ||||
INRUSH CURRENT(Typ.) | COLD START 5A(twidth=350μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | ||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 42 units (circuit breaker of type B) / 42 units (circuit breaker of type C) at 230VAC | ||||
LEAKAGE CURRENT | <0.75mA / 277VAC | ||||
NO LOAD POWER CONSUMPTION | No load power consumption <0.5W | ||||
PROTECTION | SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed. | |||
ENVIRONMENT |
WORKING TEMP. | Tcase=-40 ~ +80℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section) | |||
MAX. CASE TEMP. | Tcase=+80℃ | ||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||
STORAGE TEMP. | -40 ~ +80℃ | ||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 60℃) | ||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | ||||
SAFETY & EMC |
SAFETY STANDARDS | UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC AS/NZS IEC BS EN/EN61347-1, AS/NZS BS EN/EN61347-2-13 independent, BS EN/EN62384; IP67; GB19510.1, GB19510.14, EAC TP TC 004 approved | |||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||
EMC EMISSION |
Parameter | Standard | Test Level/Note | ||
Conducted | BS EN/EN55015(CISPR15), GB/T17743 | —– | |||
Radiated | BS EN/EN55015(CISPR15), GB/T17743 | —– | |||
Harmonic Current | BS EN/EN61000-3-2, GB/T17625.1 | Class C @load≥50% | |||
Voltage Flicker | BS EN/EN61000-3-3 | —– | |||
EMC IMMUNITY |
BS EN/EN61547 | ||||
Parameter | Standard | Test Level/Note | |||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air; Level 2, 4KV contact | |||
Radiated | BS EN/EN61000-4-3 | Level 3 | |||
EFT/Burst | BS EN/EN61000-4-4 | Level 3 | |||
Surge | BS EN/EN61000-4-5 | 2KV/Line-Line 4KV/Line-Earth | |||
Conducted | BS EN/EN61000-4-6 | Level 3 | |||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | |||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
|||
OTHERS |
MTBF | 5721.2K hrs min. Telcordia SR-332 (Bellcore) 747.1Khrs min. MIL-HDBK-217F (25℃) | |||
DIMENSION | 95*63*30mm (L*W*H) | ||||
PACKING | 0.34Kg;24pcs/ 8.67Kg/0.81CUFT for blank-type 0.35Kg;24pcs/ 8.88Kg/0.\81CUFT for B-type |
Application
‧Street lighting
‧Architectural lighting
‧Low bay lighting
‧Floodlight lighting
‧Industrial Lighting
‧Type “HL” for use in Class I, Division 2
hazardous (Classified) location.