XLG-50 series
April 29, 2022XLG-100 series
April 29, 2022MW Mean Well Meanwell 75W Constant Power Mode LED Driver XLG-75 series
Features
‧Wide input range 100~305V AC( ClassⅠ)
‧Full power output at 70~100% Constant power mode operation
‧Metal case with IP67, suitable for outdoor application
‧Class 2 power unit(except for L type)
‧Surge protection with 6KV/4KV
‧3 in 1 dimming function (Dim to off and Isolation design)
‧India (EESL) version with Input Over Voltage Protection can
survive input voltage stress of 440Vac for 48 hours
‧Protection functions: OVP/SCP/OCP/OTP
‧Life time >50,000 hrs. and 5 years warranty
Mean Well LED Driver XLG-75 Series Data Sheet Download
Description
XLG-75 series is a 75W LED AC/DC driver featuring the constant power mode.XLG-75 operates from 100~305VAC and offers models with different rated current ranging between 700mA and 5000mA. Thanks to the high efficiency up to 91%, with the fanless design, the entire series is able to operate for – 40℃~+90℃ case temperature under free air convection. The design of metal housing and IP67 ingress protection level allows this series to fit both indoor and outdoor applications. Moreover the innovative environment-adaptive capability allows this series to reliably light on the LEDs for all kinds of application environments in almost any spots that may install LED luminaires in the world. XLG-75 series comply with the latest version of IEC61347/GB7000.1-2015 and UL8750 international safety regulations. The output and dimming circuit are also completely in accordance with the new regulations with isolation to ensure the safety of both user and luminaire system during installation.
In XLG family, there are XLG-20 series, XLG-25 series, XLG-50 series, XLG-75 series, XLG-100 series, XLG-150 series, XLG-200 series, XLG-240 series and XLG-320 series.
Mean Well LED Driver XLG-75 Series Model Encoding
Type | Function | Note |
Blank | Io and Vo fixed.(For harsh environment) | By request |
A | Io adjustable via built-in potentiometer | In Stock |
AB | Io adjustable via built-in potentiometer +
3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance) |
In Stock |
Note:
1.12V and 24V models without the AB type.
2.India version needs MOQ for production, please consult MEANWELL for detail.
Specification
MODEL | XLG-75 -12- | XLG-75 -24- | |||
OUTPUT |
DC VOLTAGE | 12V | 24V | ||
CONSTANT CURRENT REGION Note.2 | 8.4~ 12V | 16.8~ 24V | |||
RATED CURRENT | 5A | 3.1A | |||
RATED POWER | 60W | 74.4W | |||
RIPPLE & NOISE (max.) Note.3 | 150mVp-p | 240mVp-p | |||
CURRENT ADJ RANGE | 2.5A~5A | 1.55A~3.1A | |||
VOLTAGE TOLERANCE Note.4 | ±3.0% | ±2.0% | |||
LINE REGULATION | ±0.5% | ±0.5% | |||
LOAD REGULATION | ±2% | ±1% | |||
SETUP, RISE TIME Note.6 | 500ms, 100ms/230VAC, 1200ms, 100ms/115VAC | ||||
HOLD UP TIME (Typ.) | 10ms/ 230VAC 10ms/ 115VAC | ||||
INPUT |
VOLTAGE RANGE Note.5 | 100 ~ 305VAC 142 ~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” section) |
|||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
POWER FACTOR | PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load | ||||
TOTAL HARMONIC DISTORTION | THD< 10%(@load≧50%/115VC,230VAC; @load≧75%/277VAC) | ||||
EFFICIENCY (Typ.) | 89% | 90% | |||
AC CURRENT | 1.0A / 115VAC 0.45A / 230VAC 0.38A/277VAC | ||||
INRUSH CURRENT(Typ.) | COLD START 50A(twidth=300μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | ||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 9 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC | ||||
LEAKAGE CURRENT | <0.75mA / 277VAC | ||||
NO LOAD POWER CONSUMPTION | No load power consumption <0.5W(for standard version) | ||||
PROTECTION |
OVER CURRENT | 95 ~ 108% | |||
Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed | |||||
SHORT CIRCUIT | Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed | ||||
OVER VOLTAGE | 13 ~ 19V | 26 ~ 36V | |||
Shut down output voltage, re-power on to recover | |||||
INPUT OVER VOLTAGE Note.7 | 320 ~ 370VAC (Shut down output voltage when the input voltage exceeds protection voltage, recovers automatically after fault condition is removed) | ||||
Can survive input voltage stress of 440Vac for 48 hours @ tc 75℃ max | |||||
OVER TEMPERATURE | Shut down output voltage, re-power on to recover | ||||
ENVIRONMENT |
WORKING TEMP. | Tcase=-40 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section) | |||
MAX. CASE TEMP. | Tcase=+90℃ | ||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +90℃, 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 60℃) | ||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | ||||
EMC SAFETY & |
SAFETY STANDARDS Note.7 | UL8750(type”HL”), UL879, CSA C22.2 No. 250.13-12;ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384; GB19510.1,GB19510.14; EAC TP TC 004;J61347-1(H29), J61347-2-13(H29),KC61347-1,KC61347-2-13,IS15885(Part2/Sec13)
(for XLG-75I type only); OM-058-SCFI-2017(except for Blank type);IP67 approved |
|||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||
EMC EMISSION |
Parameter | Standard | Test Level/Note | ||
Conducted | BS EN/EN55015(CISPR15) ,GB/T17743 | —– | |||
Radiated | BS EN/EN55015(CISPR15) ,GB/T17743 | —– | |||
Harmonic Current | BS EN/EN61000-3-2 ,GB/T17625.1 | Class C @load≥50% | |||
Voltage Flicker | BS EN/EN61000-3-3 | —– | |||
EMC IMMUNITY |
BS EN/EN61547 | ||||
Parameter | Standard | Test Level/Note | |||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | |||
Radiated | BS EN/EN61000-4-3 | Level 3 | |||
EFT/Burst | BS EN/EN61000-4-4 | Level 3 | |||
Surge | BS EN/EN61000-4-5 | 4KV/Line-Line 6KV/Line-Earth | |||
Conducted | BS EN/EN61000-4-6 | Level 3 | |||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | |||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
|||
OTHERS |
MTBF | 1232.28K hrs min. Telcordia SR-332 (Bellcore) ; 376.3Khrs min. MIL-HDBK-217F (25℃) | |||
DIMENSION | 140*63*32mm (L*W*H) | ||||
PACKING | 0.58Kg;24pcs /15Kg /0.85CUFT |
MODEL | XLG-75 -L- | XLG-75 -H- | ||||||
OUTPUT |
RATED CURRENT | 700mA | 1400mA | |||||
RATED POWER | 74.9W | 75.6W | ||||||
CONSTANT CURRENT REGION | 53 ~ 107V | 27 ~ 56V | ||||||
FULL POWER CURRENT RANGE | 700~1050mA | 1300~2100mA | ||||||
OPEN CIRCUIT VOLTAGE (max.) | 115V | 60V | ||||||
CURRENT ADJ. RANGE | 350~1050mA | 650~2100mA | ||||||
CURRENT RIPPLE | 3.0%(@rated current) | |||||||
CURRENT TOLERANCE | ±5% | |||||||
SET UP TIME | 500ms/230VAC, 1200ms/115VAC | |||||||
INPUT |
VOLTAGE RANGE |
Note.5 |
100 ~ 305VAC 142VDC ~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” ang “ DRIVING METHODS OF LED MODULE”section) |
|||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
POWER FACTOR (Typ.) | PF≧0.97 / 115VAC, PF≧0.95 / 230VAC, PF≧0.92 / 277VAC at full load
(Please refer to “Power Factor Characteristic” section) |
|||||||
TOTAL HARMONIC DISTORTION | THD< 10% (@ load≧50% at 115VAC/230VAC ,@load≧75% at 277VAC) Please refer to “TOTAL HARMONIC DISTORTION (THD)” section | |||||||
EFFICIENCY (Typ.) | 91% | 90% | ||||||
AC CURRENT (Typ.) | 1A / 115VAC 0.45A / 230VAC 0.38A / 277VAC | |||||||
INRUSH CURRENT(Typ.) | COLD START 50A(twidth=300μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | |||||||
MAX. NO. of PSUs on 16A CIRCUIT BREAKER | 9 unit(circuit breaker of type B) / 14 units(circuit breaker of type C) at 230VAC | |||||||
LEAKAGE CURRENT | <0.75mA / 277VAC | |||||||
STANDBY
POWER CONSUMPTION |
Standby power consumption <0.5W for AB-Type(Dimming OFF)(for standard version) | |||||||
PROTECTION |
OVER POWER | 110 ~ 150% | ||||||
Hiccup mode, recovers automatically after fault condition is removed | ||||||||
SHORT CIRCUIT | Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed | |||||||
INPUT OVER VOLTAGE Note.7 | 320 ~ 370VAC (Shut down output voltage when the input voltage exceeds protection voltage, recovers automatically after fault condition is removed) | |||||||
Can survive input voltage stress of 440Vac for 48 hours @ tc 75℃ max | ||||||||
OVER TEMPERATURE | Shut down output voltage, re-power on to recovery | |||||||
ENVIRONMENT |
WORKING TEMP. | Tcase=-40 ~ +90℃(Please refer to “OUTPUT LOAD vs TEMPERATURE” section) | ||||||
MAX. CASE TEMP. | Tcase=+90℃ | |||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 60℃) | |||||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||
SAFETY & EMC |
SAFETY STANDARDS Note.7 | UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384;
GB19510.1,GB19510.14; EAC TP TC 004;J61347-1(H29), J61347-2-13(H29),KC61347-1,KC61347-2-13,IS15885(Part2/Sec13) (for XLG-75I type only); NOM-058-SCFI-2017(except for Blank type);IP67 approved |
||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||
EMC EMISSION |
Parameter | Standard | Test Level/Note | |||||
Conducted | BS EN/EN55015(CISPR15) ,GB/T17743 | —– | ||||||
Radiated | BS EN/EN55015(CISPR15) ,GB/T17743 | —– | ||||||
Harmonic Current | BS EN/EN61000-3-2 ,GB/T17625.1 | Class C @load≥50% | ||||||
Voltage Flicker | BS EN/EN61000-3-3 | —– | ||||||
EMC IMMUNITY |
BS EN/EN61547 | |||||||
Parameter | Standard | Test Level/Note | ||||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | ||||||
Radiated | BS EN/EN61000-4-3 | Level 3 | ||||||
EFT/Burst | BS EN/EN61000-4-4 | Level 3 | ||||||
Surge | BS EN/EN61000-4-5 | 4KV/Line-Line 6KV/Line-Earth | ||||||
Conducted | BS EN/EN61000-4-6 | Level 3 | ||||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | ||||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
||||||
OTHERS |
MTBF | 1232.28K hrs min. | Telcordia SR-332 (Bellcore) ; 376.3Khrs min. | MIL-HDBK-217F (25℃) | ||||
DIMENSION | 140*63*32mm (L*W*H) | |||||||
PACKING | 0.58Kg;24pcs /15Kg /0.85CUFT |
Application
‧Skyscraper lighting
‧Street lighting
‧Floodlight Lighting
‧Stage lighting
‧Fishing lighting
‧Horticulture lighting
‧Bay lighting
‧DMX power supply
‧Type HL for use in classⅠ, Division 2