XLG-150 series
April 29, 2022XLG-240 series
April 29, 2022MW Mean Well Meanwell 200W Constant Power Mode LED Driver XLG-200 series
Features
‧Wide input range 100~305V AC( Class I)
‧Full power output at 70~100% Constant power mode operation
‧Metal case with IP67, suitable for outdoor application
‧Surge protection with 6KV/4KV (10KV/6KV optional)
‧3 in 1 dimming function (Dim to off and Isolation design)
‧India (EESL) version with Input Over Voltage Protection can
survive input voltage stress of 440Vac for 48 hours
‧Protection functions: OVP/SCP/OCP/OTP
‧Life time >50,000 hrs. and 5 years warranty
Mean Well LED Driver XLG-200 Series Data Sheet Download
Description
XLG-200 series is a 200W LED AC/DC driver featuring the constant power mode. XLG-200 operates from 100~305VAC and offers models with different rated current ranging between 700mA and 16A. Thanks to the high efficiency up to 94%, with the fanless design, the entire series is able to operate for -40℃~+90℃ case temperature under free air convection. The design of metal housing and IP67 ingress protection level allows this series to fit both indoor and outdoor applications. Moreover, the innovative environment-adaptive capability allows this series to reliably light on the LEDs for all kinds of application environments in almost any spots that may install LED luminaires in the world. XLG- 200 series comply with the latest version of IEC61347/ GB7000.1- 2015 and UL8750 international safety regulations. The output and dimming circuit are also completely in accordance with the new regulations with isolation to ensure the safety of both user and luminaire system during installation.
In XLG family, there are XLG-20 series, XLG-25 series, XLG-50 series, XLG-75 series, XLG-100 series, XLG-150 series, XLG-200 series, XLG-240 series and XLG-320 series.
Mean Well LED Driver XLG-200 Series Model Encoding
Type | Function | Note |
Blank | Io and Vo fixed.(For harsh environment) | By request |
A | Io adjustable via built-in potentiometer | In Stock |
AB | Io adjustable via built-in potentiometer +
3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance) |
In Stock |
Note:
1.12V and 24V models without the AB type.
2.India version needs MOQ for production, please consult MEANWELL for detail.
Specification
MODEL | XLG-200 -12- | XLG-200 -24- | |||
OUTPUT |
DC VOLTAGE | 12V | 24V | ||
CONSTANT CURRENT REGION Note.2 | 8.4~ 12V | 16.8~ 24V | |||
RATED CURRENT | 16A | 8.3A | |||
RATED POWER | 192W | 199.2W | |||
RIPPLE & NOISE (max.) Note.3 | 150mVp-p | 240mVp-p | |||
CURRENT ADJ. RANGE | Adjustable for A-Type only (via the built-in potentiometer) | ||||
8 ~ 16A | 4.15 ~ 8.3A | ||||
VOLTAGE TOLERANCE Note.4 | ±3.0% | ±2.0% | |||
LINE REGULATION | ±0.5% | ±0.5% | |||
LOAD REGULATION | ±2% | ±1% | |||
SETUP, RISE TIME Note.6 | 500ms, 100ms/230VAC, 1200ms, 100ms/115VAC | ||||
HOLD UP TIME (Typ.) | 10ms/ 230VAC 10ms/ 115VAC | ||||
INPUT |
VOLTAGE RANGE Note.5 | 100 ~ 305VAC 142 ~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” section) |
|||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
POWER FACTOR | PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load | ||||
TOTAL HARMONIC DISTORTION | THD< 10%(@load≧50%/115VC,230VAC; @load≧75%/277VAC) | ||||
EFFICIENCY (Typ.) | 92% | 94% | |||
AC CURRENT | 2.2A / 115VAC 1.1A / 230VAC 0.9A/277VAC | ||||
INRUSH CURRENT(Typ.) | COLD START 65A(twidth=550μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | ||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | ||||
LEAKAGE CURRENT | <0.75mA / 277VAC | ||||
NO LOAD POWER CONSUMPTION | No load power consumption <0.5W(for standard version) | ||||
PROTECTION |
OVER CURRENT | 95 ~ 108% | |||
Hiccup mode or constant current limiting, recovers automatically after fault condition is removed | |||||
SHORT CIRCUIT | Hiccup mode or constant current limiting, recovers automatically after fault condition is removed | ||||
OVER VOLTAGE | 13.5 ~ 18V | 27 ~ 34V | |||
Shut down output voltage, re-power on to recover | |||||
INPUT OVER VOLTAGE Note.7 | 320 ~ 390VAC (Shut down output voltage when the input voltage exceeds protection voltage, recovers automatically after fault condition is removed) | ||||
Can survive input voltage stress of 440Vac for 48 hours @ tc 75℃ max | |||||
OVER TEMPERATURE | Shut down output voltage, re-power on to recover | ||||
ENVIRONMENT |
WORKING TEMP. | Tcase=-40 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section) | |||
MAX. CASE TEMP. | Tcase=+90℃ | ||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +90℃, 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 60℃) | ||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | ||||
EMC SAFETY & |
SAFETY STANDARDS Note.7 |
UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384;GB19510.1, GB19510.14;EAC TP TC 004;J61347-1(H29), J61347-2-13(H29),KC61347-1,KC61347-2-13,IS15885(Part2/Sec13)(for XLG-200I type only );
NOM-058-SCFI-2017(except for Blank type);IP67 approved |
|||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||
EMC EMISSION |
Parameter | Standard | Test Level/Note | ||
Conducted | BS EN/EN55015(CISPR15) ,GB/T17743 | —– | |||
Radiated | BS EN/EN55015(CISPR15) ,GB/T17743 | —– | |||
Harmonic Current | BS EN/EN61000-3-2 ,GB/T17625.1 | Class C @load≥50% | |||
Voltage Flicker | BS EN/EN61000-3-3 | —– | |||
EMC IMMUNITY |
BS EN/EN61547 | ||||
Parameter | Standard | Test Level/Note | |||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | |||
Radiated | BS EN/EN61000-4-3 | Level 3 | |||
EFT/Burst | BS EN/EN61000-4-4 | Level 3 | |||
Surge | BS EN/EN61000-4-5 | 4KV/Line-Line 6KV/Line-Earth(6K/10K option) | |||
Conducted | BS EN/EN61000-4-6 | Level 3 | |||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | |||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
|||
OTHERS |
MTBF | 749.06K hrs min. Telcordia SR-332 (Bellcore) ; 200.67Khrs min. MIL-HDBK-217F (25℃) | |||
DIMENSION | 199*63*35.5mm (L*W*H) | ||||
PACKING | 0.85Kg;16pcs /14.2Kg /0.72CUFT |
MODEL | XLG-200 -L- | XLG-200 -H- | ||||||
OUTPUT |
RATED CURRENT | 700mA | 3500mA | |||||
RATED POWER | 200W | 200W | ||||||
CONSTANT CURRENT REGION Note.2 | 142 ~285V | 27 ~ 56V | ||||||
FULL POWER CURRENT RANGE | 700~1050mA | 3500~5550mA | ||||||
OPEN CIRCUIT VOLTAGE (max.) | 300V | 60V | ||||||
CURRENT ADJ. RANGE | Adjustable for A/AB-Type only (via the built-in potentiometer) | |||||||
350~1050mA | 1750~5550mA | |||||||
CURRENT RIPPLE | 3.0%(@ Load≥50% rated voltage) | |||||||
CURRENT TOLERANCE | ±5% | |||||||
SET UP TIME | Note.4 | 500ms/230VAC, 1200ms/115VAC | ||||||
INPUT |
VOLTAGE RANGE |
Note.3 |
100 ~ 305VAC 142VDC ~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” ang “ DRIVING METHODS OF LED MODULE”section) |
|||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
POWER FACTOR (Typ.) | PF≧0.97 / 115VAC, PF≧0.95 / 230VAC, PF≧0.92 / 277VAC at full load
(Please refer to “Power Factor Characteristic” section) |
|||||||
TOTAL HARMONIC DISTORTION | THD< 10% (@ load≧50% at 115VAC/230VAC ,@load≧75% at 277VAC) Please refer to “TOTAL HARMONIC DISTORTION (THD)” section | |||||||
EFFICIENCY (Typ.) | 94% | 93% | ||||||
AC CURRENT (Typ.) | 2.2A / 115VAC 1.1A / 230VAC 0.9A / 277VAC | |||||||
INRUSH CURRENT(Typ.) | COLD START 65A(twidth=550μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | |||||||
MAX. NO. of PSUs on 16A CIRCUIT BREAKER | 3 unit(circuit breaker of type B) / 6 units(circuit breaker of type C) at 230VAC | |||||||
LEAKAGE CURRENT | <0.75mA / 277VAC | |||||||
STANDBY POWER CONSUMPTION | Standby power consumption <0.5W for AB-Type(Dimming OFF)(for standard version) | |||||||
PROTECTION |
SHORT CIRCUIT | Hiccup mode or Constant current limiting,recovers automatically after fault condition is removed | ||||||
OVER VOLTAGE | 301 ~ 360V | 61 ~ 85V | ||||||
Shut down output voltage, re-power on to recovery | ||||||||
INPUT OVER VOLTAGE Note.5 | 320 ~ 390VAC (Shut down output voltage when the input voltage exceeds protection voltage,recovers automatically after fault condition is removed) | |||||||
Can survive input voltage stress of 440Vac for 48 hours @ tc 75℃ max | ||||||||
OVER TEMPERATURE | Shut down output voltage, re-power on to recover | |||||||
ENVIRONMENT |
WORKING TEMP. | Tcase=-40 ~ +90℃(Please refer to “OUTPUT LOAD vs TEMPERATURE” section) | ||||||
MAX. CASE TEMP. | Tcase=+90℃ | |||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 60℃) | |||||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||
SAFETY & EMC |
SAFETY STANDARDS Note.5 |
UL8750(type”HL”), CSA C22.2 No. 250.13-12; BS EN/ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384;GB19510.1, GB19510.14;EAC TP TC 004; J61347-1(H29), J61347-2-13(H29),KC61347-1,KC61347-2-13,IS15885(Part2/Sec13)(for XLG-200I type only );
NOM-058-SCFI-2017(except for Blank type);IP67 approved |
||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC | I/P-FG:2KVAC | O/P-FG:1.5KVAC | |||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||
EMC EMISSION | Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧50%); BS EN/EN61000-3-3 | |||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level (surge immunity Line-Earth 6 KV, Line-Line 4KV) (10K/6KV option) | |||||||
EMC EMISSION |
Parameter | Standard | Test Level/Note | |||||
Conducted | BS EN/EN55015(CISPR15) ,GB/T17743 | —– | ||||||
Radiated | BS EN/EN55015(CISPR15) ,GB/T17743 | —– | ||||||
Harmonic Current | BS EN/EN61000-3-2 ,GB/T17625.1 | Class C @load≥50% | ||||||
Voltage Flicker | BS EN/EN61000-3-3 | —– | ||||||
EMC IMMUNITY |
BS EN/EN61547 | |||||||
Parameter | Standard | Test Level/Note | ||||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | ||||||
Radiated | BS EN/EN61000-4-3 | Level 3 | ||||||
EFT/Burst | BS EN/EN61000-4-4 | Level 3 | ||||||
Surge | BS EN/EN61000-4-5 | 4KV/Line-Line 6KV/Line-Earth(6K/10K option) | ||||||
Conducted | BS EN/EN61000-4-6 | Level 3 | ||||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | ||||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
||||||
OTHERS |
MTBF | 749.06Khrs min. Telcordia SR-332(Bellcore) ; 200.67Khrs min. MIL-HDBK-217F (25℃) | ||||||
DIMENSION | 199*63*35.5mm (L*W*H) | |||||||
PACKING | 0.85Kg;16pcs/14.2Kg/0.72CUFT |
Application
‧Skyscraper lighting
‧Street lighting
‧Floodlight Lighting
‧Stage lighting
‧Fishing lighting
‧Horticulture lighting
‧Bay lighting
‧DMX power supply
‧Type HL for use in classⅠ, Division 2